The largest database of trusted experimental protocols

Xylose

Manufactured by HiMedia
Sourced in India

Xylose is a monosaccharide, or simple sugar, that is commonly found in the hemicellulose of plant cell walls. It serves as a core component in various laboratory applications, including biochemical research, fermentation processes, and the analysis of carbohydrate compositions.

Automatically generated - may contain errors

4 protocols using xylose

1

Quantification of Turmeric Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Dried turmeric powder of C. longa species and 95% pure curcuminoids standard were given by Konark Herbals and Health Care, Mumbai, India.
Glycerol (>99%), ethylene glycol (>99%), 1,4-butanediol (>98%), lactic acid (>98%), malic acid (99%), citric acid (>99%), and choline chloride (98%) were purchased from S. D. Fine Chemical, India. Xylose, glucose, and fructose were obtained from Hi Media Laboratories Pvt. Ltd., India). Analytical grade ethanol (99%) and HPLC grade acetonitrile, methanol, and tetrahydrofuran (THF) were procured from Thomas Baker Chemicals Pvt. Ltd. India. Deionised water, purified through Millipore Milli Q 50 HPLC grade, was used.
+ Open protocol
+ Expand
2

Synthesis and Characterization of Deep Eutectic Solvents

Check if the same lab product or an alternative is used in the 5 most similar protocols
Menthol (M) (2216-51-5) and bovine serum albumin (9048-46-8) and other assay chemicals were purchased from Sigma-Aldrich USA with 97% purity. Glucose (G) (50-99-7), fructose (F) (57-48-7), xylose (X) (58-86-6), maltose (M) (69-79-4), lactose (L) (63-42-3) and sucrose (S) (57-50-1), Na2SO4 (7757-82-6), K2HPO4 (7758-11-4), Na2CO3 (497-19-8)and growth medium (Luria–Bertani broth media (M1245)) were obtained from Himedia, India with a purity standard greater than 95%. All the chemicals used and their purification method is detailed in Table 3.

Source and purity various chemicals used for DES synthesis.

Chemical nameCAS reg. no.SupplierMass % purities stated by suppliersPurification method
Menthol2216-51-5Sigma-aldrich0.99 w/wOvernight storage in dessicator
Sodium sulphate54664-61-8Himedia0.97 w/wOvernight storage in dessicator
Potassium phosphate7758-11-4Himedia0.97 w/wOvernight storage in dessicator
Sodium carbonate497-19-8Himedia0.97 w/wOvernight storage in dessicator
Glucose50-99-7Sigma-aldrich0.99 w/wNone
Fructose58-49-7Sigma-aldrich0.99 w/wNone
sucrose57-50-1Merck> 98 w/wNone
xylose609-06-3Merck> 98 w/wNone
Maltose69-79-4Merck> 98 w/wNone
lactose63-42-3Merck> 98 w/wNone
+ Open protocol
+ Expand
3

Preparation and Characterization of Natural Deep Eutectic Solvents

Check if the same lab product or an alternative is used in the 5 most similar protocols
Benzyl trimethyl ammonium chloride, Bovine Serum Albumin and Naringin were procured from Sigma-Aldrich, USA. Lactose, Maltose, Fructose, Sucrose, Xylose, Sodium Sulphate, Di-Potassium Hydrogen Phosphate and Sodium Carbonate were procured from Himedia, India. The purity of each chemical used in the current investigation is provided in Table 1.

Source and purity of chemicals used in the preparation of NADES and extractive fermentation.

Chemical nameCAS Reg. no.SupplierMass % purities stated by suppliers
Benzyl trimethyl ammonium chloride (BMC)56-93-9Sigma-aldrich0.99 w/w
Bovine Serum Albumin9048-46-8Sigma-aldrich0.99 w/w
Naringin10236-47-2Sigma-aldrich0.99 w/w
Lactose (L)63-42-3Himedia0.97 w/w
Fructose (F)58-49-7Himedia0.97 w/w
Sucrose (S)57-50-1Himedia0.97 w/w
Xylose (X)609-06-3Himedia0.97 w/w
Maltose (M)69-79-4Himedia0.97 w/w
Sodium sulphate54664-61-8Himedia0.97 w/w
Di-Potassium Hydrogen Phosphate7758-11-4Himedia0.97 w/w
Sodium carbonate207-838-8Himedia0.97 w/w
+ Open protocol
+ Expand
4

Characterization of Carbohydrate Interactions

Check if the same lab product or an alternative is used in the 5 most similar protocols
Benzyl trimethyl ammonium chloride, Bovine Serum Albumin and Naringin were procured from Sigmaaldrich, USA. Lactose, Maltose, Fructose, Sucrose, Xylose, Sodium Sulphate, Di-Potassium Hydrogen Phosphate and Sodium Carbonate were procured from Himedia, India. The purity of each chemical used in the current investigation is provided in Table 1.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!