The largest database of trusted experimental protocols

Thermo q exactive focus mass spectrometer

Manufactured by Thermo Fisher Scientific
Sourced in United States

The Thermo Q Exactive Focus mass spectrometer is a high-resolution, high-mass-accuracy instrument designed for targeted and untargeted analysis. It features a quadrupole mass filter and an Orbitrap mass analyzer.

Automatically generated - may contain errors

2 protocols using thermo q exactive focus mass spectrometer

1

Serum Metabolite Extraction for UPLC-MS/MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
After the samples were slowly thawed at 4°C in a salt-ice bath, 100 µl serum sample was precisely transferred by a pipettor to the 1.5 ml centrifuge tubes. Metabolites were extracted using a 400 µl methanol: water (4:1, v/v) solution with 0.02 mg/ml L-2-chlorophenylalanin as an internal standard, vortexed for 30 s, and extracted with low-temperature ultrasound for 30 min (5°C, 40 kHz). After extraction, the samples were left to stand at −20°C for 30 min. The sample was centrifuged (13000 rpm, 4°C, 15 min), and the supernatant was transferred to an UPLC-MS/MS injection vial for detection. Liquid chromatographic separations were performed on a Thermo Ultimate 3000 system (Thermo Fisher Scientific Inc., Waltham, MA, U.S.A.) equipped with a Waters ACQUITY UPLC® HSS T3 column (150 × 2.1 mm, 1.8 μm). Mass spectrometry operations were performed on a Thermo Q Exactive Focus mass spectrometer (Thermo Fisher Scientific Inc., Waltham, MA, U.S.A.) with spray voltages of 3.8 kV in positive ion mode (ESI+) and −2.5 kV in negative ion mode (ESI−), respectively.
A pooled quality control (QC) sample was prepared by mixing equal volumes of all samples. Metabolomics data have been deposited to the EMBL-EBI MetaboLights database (DOI: 10.1093/nar/gkz1019, PMID:31691833) with the identifier MTBLS4245. The complete dataset can be accessed here https://www.ebi.ac.uk/metabolights/MTBLS4245.
+ Open protocol
+ Expand
2

Lipidome Analysis of ADe-Treated Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum samples from 400 mg/kg ADe-treated HFD-fed mice, vehicle-treated HFD-fed mice, and vehicle-treated NCD-fed mice (n = 3) were randomly collected for lipidome analysis. The samples were analyzed via LC-MS/ESI-MSn using a Thermo Ultimate 3000 system equipped with an ACQUITY UPLC BEH C18 column and a Thermo Q Exactive Focus mass spectrometer (Thermo Fisher Scientific), as described in our previous study [23 (link)]. Significant statistical differences in the metabolites (p ≤ 0.05) and variable importance in projection values ≥1.0 were regarded as the standard values for differential lipids to filter out biomarkers.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!