The largest database of trusted experimental protocols

Ecat exact hr pet camera

Manufactured by Siemens
Sourced in United States

The ECAT Exact HR + PET camera is a positron emission tomography (PET) imaging system designed for high-resolution imaging. It is capable of acquiring PET data and producing 3D images of the body's internal structures and functions.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using ecat exact hr pet camera

1

Myocardial Blood Flow Quantification Using PET

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fifty (63%) patients between 1993 and 2005 were studied in an ECAT-951/31 PET system (Siemens/CTI, Knoxville, Tennessee, USA), as previously reported.12 (link) Twenty-three (29%) patients between 2005 and 2009 were studied in an ECAT Exact HR + PET camera (Siemens, Hoffman Estates, IL, USA), as previously reported.13 (link) Six (8%) patients between 2009 and 2015 were studied in a whole-body 64-slice PET/CT scanner Biograph True Point (Siemens Healthcare, Erlangen, Germany), as previously reported.14 (link) In brief, imaging acquisition started in resting conditions after a Nitrogen-13 ammonia i.v. injection. Following the part of the study at rest, pharmacological stress was induced with dipyridamole or adenosine. After the pharmacological stress, a second dose of Nitrogen-13 ammonia was injected i.v. and imaging acquisition was performed. Dynamic datasets were obtained at rest and under stress conditions. Dynamic rest and stress MBF data were expressed in ml/gr/min myocardial tissue. Myocardial blood flow quantifications were assessed by the Hutchins 2-tissue-compartment model.15 (link) MFR was quantified as the ratio of stress MBF to rest MBF. Abnormal MFR was considered < 2.0 and abnormal stress MBF was considered < 1.9 ml/gr/min.16 (link)
+ Open protocol
+ Expand
2

Cardiac PET Imaging with Radiotracers

Check if the same lab product or an alternative is used in the 5 most similar protocols
A Siemens ECAT Exact HR+ PET camera was used for all studies. For the cardiac PET studies, a 90-min dynamic sequence (12×10 s, 2×30 s, 2×60 s, 2×150 s, 2×300 s, and 7×600 s) was acquired after i.v. injection of [18F]4F-MHPG or [18F]3F-PHPG. Images were reconstructed using iterative OSEM (4 iterations, 8 subsets), zoom = 2.2 and 7-mm Gaussian filter. Six venous blood samples (2–3 mL) were drawn during each scan to assess radiotracer metabolism in plasma and activity partitioning between plasma and red blood cells.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!