Synapt g2 si esi ms mass spectrometer

Manufactured by Waters Corporation
Sourced in United States

The Synapt G2-Si ESI MS mass spectrometer is a high-performance liquid chromatography-mass spectrometry (LC-MS) system designed for analytical applications. It utilizes electrospray ionization (ESI) to generate ions from liquid samples and a quadrupole time-of-flight (QTOF) mass analyzer to provide accurate mass measurements and high-resolution data.

Automatically generated - may contain errors

2 protocols using synapt g2 si esi ms mass spectrometer

1

Mass Spectrometry Characterization of Tripyridylamides

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mass spectra were obtained using either MALDI-TOF Voyager DE Pro (Yale, CBIC center) or University of Illinois Mass Spec. Facility. High-resolution electrospray ionization mass spectra were obtained using the Waters Synapt G2-Si ESI MS mass spectrometer. For MALDI-TOF, trans-2-[3-(4-tert-Butylphenyl)-2-methyl-2-propenylidene] malononitryile from Sigma Aldrich (St. Louis, MI) was used as the matrix. The MALDI-TOF spectra were collected using a N2 laser (337 nm wavelength), with an average of 500 shots per sample with a delayed time of 100 ns between each shot. Elemental analyses of tripyridylamides (ADM-2 to ADM-9) were carried out using PerkinElmer 2400 Series II CHNS/O Elemental Analyzer.
+ Open protocol
+ Expand
2

Optimized Small-Molecule Purification Procedure

Check if the same lab product or an alternative is used in the 5 most similar protocols
Final steps of small-molecule purification was conducted by high-performance liquid chromatography using a Varian ProStar with VYDAC reverse-phase columns (4.6 × 100 mm, 1 ml min−1, analytical; 10 × 100 mm, 3 ml min−1, semi-preparation; Supplementary Fig. 12–58; Supplementary Methods). The mobile phase was composed of A: 5% ACN; 95% H2O; and 0.1% TFA(v/v), and B: 95% ACN; 5% H2O; and 0.08% TFA (v/v). The solution NMR spectra of small molecules were recorded on 400, 500 and 600 MHz Agilent spectrometers. The deuterated solvents used for O-tert-butyl ester protected and deprotected (O–COOH) oligoquinolines were CDCl3 and (CD3)2SO, respectively. Splitting patterns that were difficult to interpret are indicated as multiplet (m) or broad (b). Mass spectra were obtained using either MALDI-TOF Voyager DE Pro (Yale University, CBIC centre) or University of Illinois Mass Spectrometry Facility. High-resolution electrospray ionization mass spectra were obtained using the Waters Synapt G2-Si ESI MS mass spectrometer (Milford, MA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!