Au2700 chemistry immuno analyzer

Manufactured by Olympus
Sourced in United States

The AU2700 Chemistry-Immuno Analyzer is a compact, fully automated clinical chemistry and immunoassay analyzer. It is designed for high-throughput sample processing and analysis of a wide range of clinical chemistry and immunoassay parameters.

Automatically generated - may contain errors

3 protocols using au2700 chemistry immuno analyzer

1

Biochemical and Hematological Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The levels of GOT and GPT were determined in the biochemical laboratory of Soroka Medical Center via a fluorescent method (Olympus AU2700 Chemistry-Immuno Analyzer, MN, USA) and were determined based on the conversion of glutamate into alanine and aspartate in the presence of GOT and GPT, respectively. Na, K, urea, creatinine, and glucose levels were determined in the biochemical laboratory of Soroka Medical Center using a fluorescent method (Olympus AU2700 Chemistry-Immuno Analyzer, MN, USA). Hb, Ht, WBC, and PLT levels were determined in the hematology laboratory of Soroka Medical Center using an automated hematology analyzer (Sysmex XE-2100 Automated Hematology Scan, IL, USA).
+ Open protocol
+ Expand
2

Clinical Blood Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood analyses were performed at Clinical Pathology Laboratories Southeast (Augusta, Georgia). Complete blood counts with differential, fasting serum glucose, and lipid panels were analyzed by standard clinical laboratory assays. Glucose and lipids were measured using an Olympus AU2700 Chemistry-Immuno Analyzer (Olympus America, Inc., Melville, NY). CBC with differential was analyzed using a COULTER LH 750 Hematology Analyzer (Beckman Coulter, Inc., Brea, CA). hsCRP levels were measured using an enzyme-linked immunosorbent assay.
+ Open protocol
+ Expand
3

Quantitative Bilirubin Assay in Serum

Check if the same lab product or an alternative is used in the 5 most similar protocols
All specimens were tested in a single laboratory (Vandoeuvre-lès-Nancy, France). Quantitative estimation of total and conjugated fraction of serum bilirubin was assayed by the Synermed (Rosny-Sous-Bois, France) reagent using the Olympus AU2700 chemistry-immuno analyzer (Rungis, France) according to manufacturer's protocol. Direct bilirubin reagent measures the absorbance of an oxidation product of bilirubin at 700 nm. The absorbance of the cholecyanin oxidation product is directly proportional to bilirubin concentration. Conjugated bilirubin is oxidized in the presence of the electron transfer agent, KHC3, to a blue-green infrared light absorbing chromophore. Unconjugated bilirubin is not significantly detected due to the fact that it is not soluble under the conditions of the direct reaction mixture and remains bound to albumin. Serum total bilirubin is reported in mg/dL. The intra-assay coefficients of variation for total bilirubin were 0.00% and 0.99% for level 1 and level 2, respectively. The corresponding figures for conjugated bilirubin were 0.00% and 1.07%, respectively.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!