3 protocols using benzoin methyl ether

1

Synthesis of Polymeric Optical Adhesives

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were used as received unless otherwise specified. 1,3,5-Triallyl-1,3,5-triazine-2,4,6(1H,3H,5H)-trione (TTT), pentaerythritol tetrakis(3-mercaptopropionate) (PETMP), propylene glycol monomethyl ether acetate (PGMEA), and benzoin methyl ether (BME) were purchased from Sigma-Aldrich. Perfluoropolyether acrylate (CN4002) was purchased from Sartomer USA, LLC. Norland Optical Adhesives 74 was purchased from Norland Products, NJ, USA. 1H,1H,2H,2H-Perfluorodecyl acrylate (PFDA) was purchased from Alfa Aesar, MA, USA. DuPont Krytox lubricant was purchased from Kurt J. Lesker company, USA. 2-hydroxyethyl methacrylate (98%) were purchased from Acros Organics and Poly(2-hydroxymethyl methacrylate) (PHEMA) was synthesized according to our previous work.23 (link)
+ Open protocol
+ Expand
2

Synthesis and Characterization of Functionalized Hydrogels

Check if the same lab product or an alternative is used in the 5 most similar protocols
Tris hydrochloride, Tris base, sulfuric acid, sodium hydroxide, sodium dodecylsulfate, sodium bicarbonate, ethylenediaminetetraacetic acid (EDTA), sodium chloride, magnesium chloride, sodium periodate, glycidyl methacrylate (GMA), poly(ethyleneglycol) diacrylate (PEGDA, MW 575), 1-propanol, 1,4-butanediol, benzoin methyl ether (BME), sodium cyanoborohydride, 2-propanol and ethanol were obtained from Sigma-Aldrich (St. Louis, MO), Merck (Darmstadt, Germany) or Fisher Scientific (Pittsburgh, PA). All chemicals were analytical grade purity or higher.
+ Open protocol
+ Expand
3

Synthesis and characterization of polymeric materials

Check if the same lab product or an alternative is used in the 5 most similar protocols
Tris hydrochloride, Tris base, sulfuric acid, sodium hydroxide, sodium dodecylsulfate, sodium bicarbonate, ethylenediaminetetraacetic acid (EDTA), sodium chloride, magnesium chloride, sodium periodate, glycidyl methacrylate (GMA), ethylene dimethacrylate (EDMA), poly(ethyleneglycol) diacrylate (PEGDA, MW 575), 2-hydroxyethyl methacrylate (HEMA), 1-propanol, n-dodecanol, 1,4-butanediol, benzoin methyl ether (BME), guanidine hydrochloride, sodium cyanoborohydride, 2-propanol and ethanol were obtained from Sigma-Aldrich (St. Louis, MO), Merck (Darmstadt, Germany) or Fisher Scientific (Pittsburgh, PA). SYBR Green II and Quant-iT OliGreen were obtained from ThermoFisher Scientific (Waltham, MA). All chemicals were analytical grade purity or higher.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!