The largest database of trusted experimental protocols

Discovery workbench data analysis software

Manufactured by Mesoscale
Sourced in United States

DISCOVERY WORKBENCH is a data analysis software designed for scientific research. It provides tools for processing, visualizing, and analyzing experimental data. The software's core function is to enable researchers to efficiently manage, manipulate, and interpret their research data.

Automatically generated - may contain errors

3 protocols using discovery workbench data analysis software

1

Multiplex Immunoassay for Cytokine Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The analysis of inflammatory markers has been described previously.25 (link) In brief, a U-PLEX assay based on an electrochemiluminescent detection method (Meso Scale Diagnostics, Rockville, MD) was used to analyze the concentrations of 71 cytokines in plasma samples from patients (n = 13) with peripheral NeuP and healthy controls (n = 13). A MESO QUICKPLEX SQ 120 instrument equipped with DISCOVERY WORKBENCH data analysis software (Meso Scale Diagnostics, Rockville, MD) was used to collect and analyze data. Electrochemiluminescent signals from calibrators were fitted to a weighted 4-parametric logistic model to form standard curves.
+ Open protocol
+ Expand
2

Multiplex Cytokine Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The concentrations of 71 cytokines, chemokines, and growth factors were analyzed using a U-PLEX assay based on an electrochemiluminescent detection method (Meso Scale Diagnostics, Rockville, MD) according to the manufacturer's recommendations. Data were collected and analyzed using MESO QUICKPLEX SQ 120 instrument equipped with DISCOVERY WORKBENCH data analysis software (Meso Scale Diagnostics). Samples were thawed on the day of analysis, blinded, and were randomly mixed.
+ Open protocol
+ Expand
3

Salivary Inflammatory Protein Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
The concentrations of inflammatory proteins in saliva samples were analyzed from the last six healthy control subjects from the original group of 16 controls with the purpose to investigate the possibility to detect these proteins in the samples. The samples were analyzed using a commercially available V-PLEX human biomarkers (Meso Scale Diagnostics, Rockville, MD, USA) multiplex assay. The assay contained 39 biomarkers (see Table 4) and was based on an electrochemiluminescent detection method and performed exactly according to the manufacturer’s recommendations. Data were collected and analyzed using MESO QUICKPLEX SQ 120 instrument equipped with DISCOVERY WORKBENCH® data analysis software (Meso Scale Diagnostics, Rockville, MD, USA).
The precisions based on both intra- and interassay coefficient of variations were <10% within the detection limits. The detection limit for each investigated biomarker is shown in Table 4 [24 (link),25 (link)].
Total protein concentration was measured using 2D Quant-kit (GE Healthcare Biosciences AB, Uppsala, Sweden), according to the manufacturer’s protocol.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!