The largest database of trusted experimental protocols

Chromquest 5.0 software package

Manufactured by Thermo Fisher Scientific
Sourced in United States

ChromQuest 5.0 is a software package designed for data acquisition, processing, and management in liquid chromatography (LC) and gas chromatography (GC) systems. It provides a comprehensive suite of tools for instrument control, data analysis, and reporting.

Automatically generated - may contain errors

2 protocols using chromquest 5.0 software package

1

Chemical Profiling of Tea Tree Oil

Check if the same lab product or an alternative is used in the 5 most similar protocols
Gas chromatography with flame ionization detector (GC-FID) (Thermoquest Trace GC 2000, Austin, TX, USA) and DB5-MS capillary column (25 m × 0.25 mm, 0.25 μm film thickness, Agilent Technologies, Santa Clara, CA, USA) was used to analyze the chemical composition of TTO. The oven temperature was as follows: 45 °C for 1 min, 45 °C to 94 °C with 4 °C/min rise and increased to 180 °C at a rate of 2 °C/min then followed by an increase from 20 °C/min to 240 °C. Helium was the carrier gas, and the flow rate was 1.3 mL/min, splitless, injection temperature was 225 °C and FID temperature was 250 °C. TTO was diluted in 1 in a 1000 ratio for analysis by GC-FID and gas chromatography–mass spectrometry (GC–MS). Hexadecane was added to the oil as an internal standard to make a final solution equivalent to 5g per μL. The ChromQuest 5.0 Software Package (Thermo Fisher Scientific Inc. Waltham, MA, USA) was used for chromatogram analysis. The experiment was performed in triplicate.
+ Open protocol
+ Expand
2

Enantiomeric Separation of Terpenes

Check if the same lab product or an alternative is used in the 5 most similar protocols
Enantiomeric separation of terpinen-4-ol and α-terpineol was achieved with an Rt-βDEXse column (30 m, 0.32 mm × 0.25 μm column, Restek Corporation, Bellefonte, PA, USA) using a Trace GC Ultra (Thermo Scientific, Waltham, MA USA). Helium was used as a carrier gas at 1.2 mL/min. The samples were analyzed with a split ratio of 10:1. The injector and FID temperatures were 225 and 230 °C, respectively. Column temperature for terpinen-4-ol: 50–80 °C at 3 °C/min, 80−105 °C at 10 °C/min, 105−120 °C at 3 °C/min, 120−180 °C at 10 C/min and hold for 10 min; for α-terpineol: 70 °C for 3 min, 3 °C/min to 120 °C, 5 °C/min to 220 °C and hold for 10 min. The ChromQuest 5.0 Software Package (Thermo Fisher Scientific Inc. Waltham, MA, USA) was used for analysis in comparison with authentic samples. All analyses were made in triplicate.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!