Precicontrol clinchem multi 1

Manufactured by Roche

PreciControl ClinChem Multi 1 is a control material used in clinical chemistry testing. It is designed to monitor the performance of clinical chemistry assays.

Automatically generated - may contain errors

2 protocols using precicontrol clinchem multi 1

1

Analytical Measurements of Metabolic Markers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Glucose, lactate and total protein concentrations were measured on Cobas 6000 c501 biochemistry analyser (Roche Diagnostics GmbH, Mannheim, Germany) with standard methods, using reagents GLUC3 (enzymatic reference method with hexokinase), LACT2 (enzymatic method with lactate oxidase) and TPUC3 (precipitating method with benzethonium chloride), respectively (Roche Diagnostics GmbH, Mannheim, Germany). For each analyte, quality control was performed daily in two levels using PreciControl ClinChem Multi 1 and PreciControl ClinChem Multi 2 (Roche Diagnostics GmbH, Mannheim, Germany), and Precinorm PUC and Precipath PUC controls (Roche Diagnostics GmbH, Mannheim, Germany). Coefficients of variations in the tested time period were within analytical requirements for imprecision.
+ Open protocol
+ Expand
2

Internal and External Quality Control

Check if the same lab product or an alternative is used in the 5 most similar protocols
Internal quality control (IQC) results from October 2019 to December 2019 were used for our laboratory’s coefficient of variation (CV%) calculation. PreciControl Clin Chem Multi 1 and Multi 2 (level 1 lot no:250280, level 2 lot no: 324196, Roche Diagnostic GmbH, Mannheim, Germany) IQC materials were carried out two times per day. Bias estimation of all analytes were determined by twelve months of data obtained during a cycle from the external quality control program (KBUDEK, Turkey) between January 2019 and December 2019. Bias calculation was based on peer-group values using the same device and method in the external quality control (EQC) program. Among the evaluated EQC results, for all analytes, only 8 results were found outside the acceptable limits during one cycle, and were excluded from the calculation of bias, and the overall EQC success was above 95%. Regulatory-preventive action was initiated for each excluded result, and the sequent EQC result was found within acceptable limits.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!