The largest database of trusted experimental protocols

3 protocols using thc oh

1

Quantification of Cannabinoids in Serum

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reference standards for THC-d3, THC-OH, THC-OH-d3, THC-COOH-d9, CBD, CBD-d3, CBDA, CBN-d3, CBNA, CBG, CBGA, CBC, CBCA, CBL, THCV, THCVA, CBDV and CBDVA were purchased from Cerilliant (Round Rock, TX, USA), CBG-d9 and CBC-d9 from Cayman Chemical Co. (Ann Arbor, MI, USA) via LGC Standards (Wesel, Germany), CBN, THC and THC-COOH from LGC Standards and THCAA from THC Pharm (Frankfurt a. M., Germany). All standards were certified reference material and had a purity of at least 99.0%, except for THC-OH-d3, THCAA, CBC, CBC-d9, CBCA, CBL, THCVA, CBDV and CBDVA (97.7%), THC-d3 (96.7%), and CBG-d9 (95.0%). All chemicals were obtained from Carl Roth (Karlsruhe, Germany), except for methanol (from Fisher Scientific (Loughborough, UK)) and acetonitrile (from AppliChem (Darmstadt, Germany)). Chemicals used in LC-MS/MS measurement processes were LC-MS grade. All other chemicals were HPLC grade, except for acetone and dichloromethane, which had a purity of 99.8% and 99.5%, respectively. Blank human serum used for calibration was obtained from voluntary healthy blood donors via blood donation service and was tested to be drug-free.
+ Open protocol
+ Expand
2

Quantitative Analysis of THC Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
THC, THC-COOH, THC-OH, THC-D3, THC-COOH-D3, and THC-OH-D9 were purchased from Cerilliant (Round Rock, TX, USA). A second set of THC, THC-OH, and THC-COOH was purchased from Lipomed (Cambridge, MA, USA) to be used for quality control samples. Water and acetonitrile (LC–MS-grade) were obtained from Millipore (Burlington, MA, USA). Dansyl chloride, sodium bicarbonate, sodium carbonate, acetic acid, and formic acid (LC–MS-grade) were obtained from Sigma-Aldrich (St. Louis, MO, USA). Captiva EMR-Lipid columns (1 mL, 40 mg) were purchased from Agilent Technologies (Santa Clara, CA, USA). Chromatography was performed with a Kinetex Phenyl Hexyl column (3.0 × 50 mm, 2.6 μm) purchased from Phenomenex Inc. (Torrance, CA, USA).
+ Open protocol
+ Expand
3

Quantitative Analysis of Cannabinoids

Check if the same lab product or an alternative is used in the 5 most similar protocols
THC, THC-OH, THC-COOH and CBD at 1 mg/mL, and THCCOOH-glucuronide and the internal standards (IStd) THC-d3, THC-OH-d3 and THCCOOH-d3 at 0.1 mg/mL in methanol were purchased from Cerilliant (Round Rock, TX, USA). THC-diOH and THC-diOH-d6 at 0.1 mg/mL and THC-glucuronide at 0.01 mg/mL in methanol were from ElSohly Laboratories (Oxford, MS, USA). Solid phase extraction (SPE) mixed-mode cation exchange cartridges (Strata Drug X-C, 3 mL, 60 mg) were purchased from Phenomenex (Torrance, CA, USA). Formic acid was obtained from Pharmco-Aaper (Shelbyville, KY, USA). Methanol, acetonitrile, dichloromethane, and isopropanol were acquired from Fisher Scientific (Pittsburgh, PA, USA). Solvents for the extraction were high performance liquid chromatography (HPLC) grade and for the chromatographic instrument were liquid chromatography-mass spectrometry (LC-MS) grade.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!