The largest database of trusted experimental protocols

Mircury lna microrna pcr sybr green master mix

Manufactured by Qiagen

The MiRCURY LNA microRNA PCR SYBR Green master mix is a reagent designed for the quantitative detection of microRNA expression using real-time PCR technology. It contains all the necessary components, including SYBR Green dye, required for the amplification and detection of microRNA targets.

Automatically generated - may contain errors

2 protocols using mircury lna microrna pcr sybr green master mix

1

Quantifying microRNA Expression in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Total RNA was extracted using Tri-Reagent (Molecular Research Inc., Cincinnati, OH). RNA was subjected to reverse transcription and qPCR using previously published methods [17 (link)]. For microRNA, the miRCURY LNA Universal cDNA Synthesis kit (Exiqon Inc., Woburn, MA) was used for reverse transcription of microRNA. The primers were custom designed by Exiqon. The miRCURY LNA microRNA PCR SYBR Green master mix (Exiqon INC) was used for qPCR with the following cycle parameters: 95°C for 10 minutes and 45 cycles at 95°C for 10 seconds and 60°C for 60 seconds. Expression of individual miRNA was normalized to the mouse U6 gene and calculated as the difference between the threshold values of the two genes (ΔΔcq).
+ Open protocol
+ Expand
2

Quantitative Analysis of miRNA and mRNA

Check if the same lab product or an alternative is used in the 5 most similar protocols
Total RNA was extracted using Tri-Reagent (Molecular Research Inc., Cincinnati, OH, United States). For miRNA, the miRCURY LNATM Universal cDNA Synthesis kit (Exiqon Inc., Woburn, MA, United States) was used for reverse transcription of miRNA. The primers were purchased from Exiqon. The miRCURY LNA microRNA PCR SYBR Green master mix (Exiqon Inc.) was used for qPCR with the following cycle parameters: 95°C for 10 min and 40 cycles at 95°C for 10 s and 60°C for 60 s. Expression of individual microRNA was standardized to the mouse U6 gene (tissue) or miR103 (serum) (Hu et al., 2015 (link); Su et al., 2017 (link)). For mRNA we used a Thermoscript RT-PCR kit (Invitrogen, Carlsbad, CA, United States). Real-time qPCR was performed with SYBR Green PCR Reagents (Bio-Rad, Hercules, CA, United States) using the following cycle parameters: 94°C for 2 min and 40 cycles at 94°C for 15 s, 55°C for 30 s, 72°C for 30 s with final extension at 72°C for 10 min. The quantification cycle (Cq) values were defined as the number of cycles required for the fluorescence signal to exceed the detection threshold. Individual miRNA or mRNA expression was calculated as the difference between the threshold values of the two genes (2-Δcq). Melting curve analysis was routinely performed to verify the specificity of the reaction. Let-7-5p (YP00204767) was ordered from Qiagen (Germantown, MD, United States).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!