The largest database of trusted experimental protocols

Real envision hrp rabbit mouse polymer

Manufactured by Agilent Technologies

The REAL EnVision HRP Rabbit/Mouse polymer is a highly sensitive detection system for immunohistochemistry (IHC) and immunocytochemistry (ICC) applications. It utilizes a polymer-based technology to enhance the signal detection of rabbit or mouse primary antibodies, allowing for efficient visualization of target antigens.

Automatically generated - may contain errors

2 protocols using real envision hrp rabbit mouse polymer

1

Immunohistochemical Analysis of TLR7 and CD68

Check if the same lab product or an alternative is used in the 5 most similar protocols
For immunohistochemistry, heat‐induced epitope retrieval was performed with citrate buffer. Staining was performed on a DAKO autostainer plus. After blocking endogenous peroxidase, sections were incubated for 45 minutes with rabbit polyclonal Anti‐TLR7 antibody (1:50; Proteintech #17232‐1‐AP) or anti‐CD68 antibody (1:100; Dako #MO876), respectively. Sections were washed and incubated with Dako REAL EnVision HRP Rabbit/Mouse polymer, which reacts with DAB‐Chromogen, according to the manufacturer's protocol. Histology and staining results were evaluated in a blinded fashion by an experienced pathologist (C. Keber). Only cases where at least 2 independent biopsy cores could be evaluated were counted. Staining intensity was graded on a scale from 0 to 3 (absent, weak, moderate, strong), and a mean score was calculated for each patient.
+ Open protocol
+ Expand
2

VEGFA Immunohistochemistry Using EDTA Retrieval

Check if the same lab product or an alternative is used in the 5 most similar protocols
For immunohistochemistry, heat-induced epitope retrieval was performed with EDTA. Staining was performed on a DAKO autostainer plus. After blocking endogene peroxidase, sections were incubated for 45 min with mouse monoclonal anti-VEGFA antibody (1:200; Abcam no. ab1316, clone VG-1). Sections were washed and incubated with Dako REAL EnVision HRP Rabbit/Mouse polymer, which reacts with DAB chromogen, according to the manufacturer’s protocol.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!