2 protocols using g1316b column compartment

1

HPLC Analysis of Phytocannabinoids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Agilent Technologies 1200 Series HPLC system equipped with a G1315C DAD, G1316B column compartment, G1367D autosampler, and G1312B binary pump was used to analyse the acidic and neutral forms of phytocannabinoids. The separation was performed on a Phenomenex Kinetex EVO C18 column (5 μm, 100 x 2.1 mm id) with a Phenomenex SecurityGuard ULTRA guard column. Instrument control, data acquisition, and integration were done with ChemStation LC 3D Rev B.04.02 software (Agilent Technologies). A 2 μL injection volume was used for all calibration standards (THC, CBD, THC-A, CBD-A, CBG, CBG-A, all Sigma-Aldrich) and sample analysis. The compound peaks were detected for 230 nm and 280 nm. Mobile phases consisted of 50 mM ammonium formate (pH 5.19) (Sigma-Aldrich) in HPLC grade water (Fisher Chemical) on the A side and 100% methanol (Fisher Chemical) on the B side, with a flow rate 0.3 ml/min. Two samples per cultivar were analyzed, with two technical repeats per each sample. Data are presented in Table 3.
+ Open protocol
+ Expand
2

HPLC-DAD Analysis of Analytes

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC-DAD analyses were performed on an Agilent 1200 HPLC system equipped with the following modules: G1312B BinPump SL, G13798 degasser, G1367D HiP ALS SL plus autosampler, a G1316B column compartment (set at 35 °C), and a G1315C diode array detector (Agilent, Waldbronn, Germany). Data acquisition rate was 80 Hz with the scan rate set between 210 – 400 nm (spectrum step 1 nm). The injection volume was 10 μL (0.1 mg/mL analyte solution). A Synergi Max-RP (250 × 4.6 mm, 4 μm) column from Phenomenex (Macclesfield, United Kingdom) was used and analytes were eluted under gradient conditions. Mobile phase A consisted of 25 mM triethylammonium phosphate (TEAP) buffer solution and mobile phase B comprised of 70% acetonitrile and 30% water containing 25 mM TEAP. The gradient elution commenced at 70% A and decreased to 5% within 5 min. This was then held until 12 min and returned to initial conditions by a 5 min post time.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!