The largest database of trusted experimental protocols

Rab0479

Manufactured by Merck Group
Sourced in United States

RAB0479 is a laboratory equipment product from Merck Group. It serves as a core function for various scientific applications. The detailed specifications and intended use of this product are not available.

Automatically generated - may contain errors

6 protocols using rab0479

1

Lipid and Inflammatory Biomarker Assessment

Check if the same lab product or an alternative is used in the 5 most similar protocols
Triglycerides and total cholesterol concentrations were determined by enzymatic colorimetric methods using available commercial kits (Wiener lab Group, Argentina). The high-density lipoprotein cholesterol (HDLc) was determined after precipitation of very low-density lipoprotein (VLDL) and low-density lipoprotein (LDLc) with polyanions (dextran sulphate and magnesium chloride). LDL-cholesterol concentration was determined by a two-step homogeneous assay without precipitation. Free fatty acids were determined using available commercial kits (ab65341, Abcam, USA).
Circulating tumor necrosis factor-α (TNF-α) (RAB0479), interleukin-1β (IL-1β) (RAB0277), insulin (RAB0904) (all from SIGMA Aldrich, St. Louis, MO, USA), leptin (ab100773), and adiponectin (ab108784) (Abcam, USA) were performed using commercially available kits according to the manufacturer′s instructions.
Blood glucose concentrations were measured using a glucose meter (Roche Diagnostics GmbH, Mannheim, Germany). The HOMA-IR (Homeostasis model assessment of insulin resistance) index was calculated as [fasting glucose (mg/dl) × fasting insulin (ng/ml)/405] to assess insulin resistance [38 (link)].
+ Open protocol
+ Expand
2

Rat Liver Cytokine Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
The contents of interleukin (IL)-1β, IL-6 as well as tumor necrosis factor (TNF)-α in rat liver tissue homogenate were tested with corresponding rat ELISA kits (RAB0277, RAB0311, RAB0479, Sigma-Aldrich, St. Louis., MO, USA), respectively.
+ Open protocol
+ Expand
3

Hepatic and Serum Biomarker Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Hepatic levels of superoxide dismutase (SOD) and serum levels of IL-1β, IL-6, and TNF-α were determined using commercial assay kits (SOD: Cat. No. 19160; IL-1β, IL-6, and TNF-α: Cat. No. RAB0277, RAB0311, and RAB0479, respectively; Sigma-Aldrich Co.) according to the manufacturers’ instructions.
+ Open protocol
+ Expand
4

Quantifying Serum TNF-α Levels

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum levels of TNF-α were quantified by a commercial ELISA kit, according to the supplier's instructions (Sigma, RAB0479). Results were analyzed by linear regression adjustment, using the standard concentrations of TNF-α and the absorbance given at 450 nm.
+ Open protocol
+ Expand
5

Plasma Biomarker Profiling Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples were immediately separated by centrifugation at 3,500 rpm, at 4 °C for 30 min. TC, TG, and HDL-c levels in plasma were determined spectrophotometrically using specific commercial kits (Human Gesellschaft fuer Biochemica and Diagnostica mbH, Wiesbaden, Germany). Leptin levels in plasma were determined using commercial kits (RAB0335, Sigma-Aldrich, St. Louis, MO, USA). Plasma TNF-α was assayed using commercial kits (RAB0479, Sigma-Aldrich, Saint Louis, MO, USA). Liver function was determined using AST (MAK055-1KT) and ALT (MAK052-1KT) activities in serum (Sigma-Aldrich, St. Louis, MO, USA). All protocols followed the manufacturers’ instructions.
+ Open protocol
+ Expand
6

Serum Biomarker Profiling Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
We collected 2-mL blood samples and placed them in pre-cooled tubes, centrifuged at 987 g × for 10 min at 4°C. Serum levels of activities of glucose, creatinine, urea nitrogen, alanine transaminase (ALT), aspartate transaminase (AST), and gamma-glutamyl transferase (GGT) were measured using an automated biochemical analyzer (BioTek, USA). Serum IL-6 (RAB0311, SIGMA, USA) and TNF-α (RAB0479, SIGMA, USA) were detected followed the instructions of the assay kits.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!