The largest database of trusted experimental protocols

Chemstation lc 3d rev b 04

Manufactured by Agilent Technologies
Sourced in United States

ChemStation LC 3D Rev B.04.02 is a software application for the control, data acquisition, and data analysis of liquid chromatography (LC) systems. The software provides features for instrument control, method development, data processing, and reporting.

Automatically generated - may contain errors

2 protocols using chemstation lc 3d rev b 04

1

HPLC Analysis of Phytocannabinoids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Agilent Technologies 1200 Series HPLC system equipped with a G1315C DAD, G1316B column compartment, G1367D autosampler, and G1312B binary pump was used to analyse the acidic and neutral forms of phytocannabinoids. The separation was performed on a Phenomenex Kinetex EVO C18 column (5 μm, 100 x 2.1 mm id) with a Phenomenex SecurityGuard ULTRA guard column. Instrument control, data acquisition, and integration were done with ChemStation LC 3D Rev B.04.02 software (Agilent Technologies). A 2 μL injection volume was used for all calibration standards (THC, CBD, THC-A, CBD-A, CBG, CBG-A, all Sigma-Aldrich) and sample analysis. The compound peaks were detected for 230 nm and 280 nm. Mobile phases consisted of 50 mM ammonium formate (pH 5.19) (Sigma-Aldrich) in HPLC grade water (Fisher Chemical) on the A side and 100% methanol (Fisher Chemical) on the B side, with a flow rate 0.3 ml/min. Two samples per cultivar were analyzed, with two technical repeats per each sample. Data are presented in Table 3.
+ Open protocol
+ Expand
2

HPLC Analysis of Phytocannabinoids in Cannabis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Agilent Technologies 1200 Series HPLC system, equipped with a G1315C DAD, G1316B column compartment, G1367D autosampler, and G1312B binary pump was used to analyze the acidic and neutral forms of phytocannabinoids. The separation was performed on a Phenomenex Kinetex EVO C18 column (5 µm, 100 × 2.1 mm id) with a Phenomenex SecurityGuard ULTRA guard column. Instrument control, data acquisition, and integration were carried out with ChemStation LC 3D Rev B.04.02 software (Agilent Technologies, Santa Clara, United States). A 2 µL injection volume was used for all calibration standards (THC, CBD, THC-A, CBD-A, CBG, CBG-A, all Sigma-Aldrich, Montreal Canada) and sample analysis. The compound peaks were detected at 230 nm and 280 nm. Mobile phases consisted of 50 mM ammonium formate (pH 5.2) (Sigma-Aldrich) in HPLC grade water (ThermoFisher Scientific, Toronto, Canada) on the A side and 100% methanol (Fisher Chemical) on the B side, with a flow rate 0.3 mL/min. Two samples per each flower sample were analyzed, with two technical repeats per each sample.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!