The largest database of trusted experimental protocols

3 protocols using arium 611 pro vf purification system

1

Synthetic PapRIV Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Synthetic PapRIV was purchased from GL Biochem (Shanghai, China). The alanine scan, metabolites and scrambled control were synthesized using solid-phase peptide synthesis (Supplementary method S1). The quality of all peptides was determined using an in-house developed QC method and a purity of 95% or more was found for each sequence. Calcium dichloride dihydrate, magnesium sulphate, potassium chloride, sodium dihydrogen phosphate hydrate, HEPES, sodium lactate and urethane were purchased from Sigma-Aldrich (Diegem, Belgium), while Bovine Serum Albumin (BSA), sodium iodide, sodium dihydrogen phosphate monohydrate were obtained from Merck KGaA (Darmstadt, Germany). Sodium chloride and disodium hydrogen phosphate dihydrate were obtained from VWR (Leuven, Belgium). Calcium dichloride and d-glucose were purchased from Fluka (Diegem, Belgium) and dextran from AppliChem GmbH (Darmstadt, Germany). Water was purified using an Arium 611 Pro VF purification system (Sartorius, Göttingen, Germany) to laboratory-graded water (18.2 MΩ × cm).
+ Open protocol
+ Expand
2

Radiolabeling Peptides for Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Calcium dichloride dihydrate, magnesium sulphate, potassium chloride, sodium chloride, sodium dihydrogen phosphate hydrate, sodium lactate and urethane were purchased from Sigma-Aldrich (Diegem, Belgium), while Bovine Serum Albumin (BSA), disodium hydrogen phosphate dihydrate, sodium iodide, sodium dihydrogen phosphate monohydrate, sodium metabisulphite and Chloramine-T were obtained from Merck KGaA (Darmstadt, Germany). Calcium dichloride, D-glucose, formic acid (FA) and HEPES were purchased from Fluka (Diegem, Belgium) and dextran from AppliChem GmbH (Darmstadt, Germany). For the mobile phases, acetonitrile was obtained from Fisher Scientific (Erembodegem, Belgium) and water was purified using an Arium 611 Pro VF purification system (Sartorius, Göttingen, Germany) to laboratory-graded water (18.2 MΩ × cm). For the radiolabeling of the peptides, Iodo-Gen® coated tubes were purchased from Thermo Scientific (Erembodegem, Belgium) and the radioactive sodium iodide solution (Na125I) from Perkin Elmer (Zaventem, Belgium).
+ Open protocol
+ Expand
3

Synthetic PapRIV Peptide Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Synthetic PapRIV was purchased from GL Biochem (Shanghai, China). The alanine scan, metabolites and scrambled control were synthesized using solid-phase peptide synthesis (Supplementary method S1). The quality of all peptides was determined using an in-house developed QC method and a purity of 95% or more was found for each sequence. Calcium dichloride dihydrate, magnesium sulphate, potassium chloride, sodium dihydrogen phosphate hydrate, HEPES, sodium lactate and urethane were purchased from Sigma-Aldrich (Diegem, Belgium), while Bovine Serum Albumin (BSA), sodium iodide, sodium dihydrogen phosphate monohydrate were obtained from Merck KGaA (Darmstadt, Germany). Sodium chloride and disodium hydrogen phosphate dihydrate were obtained from VWR (Leuven, Belgium).
Calcium dichloride and D-glucose were purchased from Fluka (Diegem, Belgium) and dextran from AppliChem GmbH (Darmstadt, Germany). Water was purified using an Arium 611 Pro VF purification system (Sartorius, Göttingen, Germany) to laboratory-graded water (18.2 MΩ × cm).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!