The largest database of trusted experimental protocols

Luminex 100 bio plex liquid array multiplexing system fluorescent reader

Manufactured by Bio-Rad

The Luminex 100 Bio-Plex Liquid Array Multiplexing System Fluorescent Reader is a laboratory instrument designed for the detection and quantification of multiple analytes in a single sample. The system utilizes fluorescent-coded beads to simultaneously measure a variety of biomolecules, such as proteins, cytokines, and nucleic acids.

Automatically generated - may contain errors

3 protocols using luminex 100 bio plex liquid array multiplexing system fluorescent reader

1

Multiplex Cytokine Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Supernatants from whole blood stimulated for 18 hours were thawed. Concentrations of IL-12p40, IL-12p70, IL-10, IL-6 and TNF-α were measured for all samples by Milliplex MAP Multiplex Immunoassay (based on Luminex MAP technology; Millipore Corporation) on a Bio-Rad Luminex 100 Bio-Plex Liquid Array Multiplexing System Fluorescent Reader, according to the manufacturer’s instruction. Concentrations of the standards in 200µL assay buffer ranged from 10000, 2000, 400, 80, 16 to 3.2 pg/mL. A sample volume of 25µL either diluted 2- or 25-fold was used.
+ Open protocol
+ Expand
2

Multiplex Cytokine Analysis of BCG-Stimulated Blood

Check if the same lab product or an alternative is used in the 5 most similar protocols
Supernatants from whole blood stimulated for 6 days with BCG were thawed. Concentrations of IL-1β, IL-4, IL-6, IL-10, IL-17, IL-22, IL-23, IFNγ, and TNFα were measured for all samples by Milliplex MAP Multiplex Immunoassay (based on Luminex MAP technology; Millipore) on a Bio-Rad Luminex 100 Bio-Plex Liquid Array Multiplexing System Fluorescent Reader, according to the manufacturer’s instruction. The following concentrations of the standards in 200 ml assay buffer were used: 10,000, 2,000, 400, 80, 16, and 3.2 pg/ml.
+ Open protocol
+ Expand
3

Multiplex Cytokine Profiling in Whole Blood

Check if the same lab product or an alternative is used in the 5 most similar protocols
Concentrations of IL1β, IL4, IL6, IL10, IL17, IL22, IL23, IFNγ, TNFα were measured in supernatants from whole blood stimulated for 6 days by Milliplex MAP Multiplex Immunoassay (based on Luminex MAP technology; Millipore) on a Bio-Rad Luminex 100 Bio-Plex Liquid Array Multiplexing System Fluorescent Reader, according to the manufacturer’s instructions. The following concentrations of the standards diluted in 200 μl assay buffer were used: 10000, 2000, 400, 80, 16, and 3.2 pg/ml.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!