The largest database of trusted experimental protocols

Empower 3 chromatographic software

Manufactured by Waters Corporation
Sourced in United States

Empower 3 is a chromatographic software from Waters Corporation. It is designed to control and manage chromatographic data acquisition and processing.

Automatically generated - may contain errors

3 protocols using empower 3 chromatographic software

1

HPLC Analysis of 10-HDA Content

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 10-HDA content in samples was analyzed with the HPLC method using a Waters 2695 chromatographic system, with diode matrix detector Waters 996. The chromatographic conditions were two eluents: trifluoroacetic acid and acetonitrile. The columns were ACE C18 (250 × 4, 6 mm), the volume of injection was 10 µL, the speed of injection was 1 mL/min, the column temperature was 25 °C, and the wavelength for detection was 210 nm. The concentrations were determined and summarized using the Empower 3 chromatographic Software (Waters Corporation, Milford, CT, USA).
+ Open protocol
+ Expand
2

Quantifying 10-HDA in Lithuanian RJ

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 10-HDA content in the samples of Lithuanian RJ were analysed by the HPLC method using the Waters 2695 chromatographic system, with a diode matrix detector Waters 996. The chromatographic conditions were the following: two eluents trifluoroacetic acid, as well as acetonitrile.
The column used was ACE C18 (250 × 4.6 mm), the volume of injection 10 µl, the speed of injection 1 ml/min, temperature in the column 25°C and the wavelength for detection 210 nm. Then the concentrations were determined and summarized using the Empower 3 chromatographic Software (Waters corporation, Milford, USA).
+ Open protocol
+ Expand
3

HPLC Analysis of 10-HDA Content

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 10-HDA content in samples was analyzed with the HPLC method using the Waters 2695 chromatographic system, with diode matrix detector Waters 996. The chromatographic conditions were two eluents trifluoroacetic acid and acetonitrile. The columns were ACE C18 (250 × 4, 6 mm), the volume of injection 10 µL, the speed of injection 1 mL/min, temperature in column 25 • C, and the wavelength for detection 210 nm. The concentrations were determined and summarized using the Empower 3 chromatographic Software (Waters Corporation, Milford, MA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!