The largest database of trusted experimental protocols

Gc ms model 7890a

Manufactured by Agilent Technologies

The Agilent 7890A Gas Chromatograph coupled with a Mass Spectrometer (GC-MS) is an analytical instrument designed for the separation, identification, and quantification of chemical compounds. It combines the high-resolution separation capabilities of gas chromatography with the powerful identification and structural elucidation capabilities of mass spectrometry.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using gc ms model 7890a

1

Ethylacetate Fraction Chemical Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Identification of constituents of ethylacetate partitioned fraction of A. digitata using HRGC-MS. The GC-MS analysis was performed using Agilent Technologies GC-MS (Model 7890A) equipped with Agilent 19091 S–433HP-5MS 5% phenyl methyl polysiloxane column (30 m × 250 μm x 0.25μm f.t). The analysis works on the principle that a mixture will separate into individual substances when heated. Pure helium gas was used as a carrier gas at a flow rate of 1.5 mL/min. GC-MS analysis resulting in chromatogram was compared to complete library using data base of National Institute of Standard and Technology (NIST).
+ Open protocol
+ Expand
2

GC/MS Analysis of A. comosus Extract

Check if the same lab product or an alternative is used in the 5 most similar protocols
A concentrated extract of A. comosus was dissolved in methanol and the solution was used for the GC/MS analysis. The analysis was performed using Agilent Technologies GC/MS (Model 7890A) equipped with Agilent 19091IS-433HP-5MS 5% Phenyl Methyl Silox column (30 m × 250 µm × film thickness 0.25 µm) coupled with mass spectrometry. Pure helium gas as carrier gas at 1.5 mL/min constant rate was used. The injector temperature was 250 ºC.
GC/MS analysis resulting in chromatogram was compared to the complete library using a data base of the National Institute of Standard and Technology (NIST). The values were presented as the relative percentage of the chemical components expressed as a percentage by peak area. The GC/MS profiling was performed at the Department of Chemical Engineering, University of Ilorin, Ilorin, Nigeria.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!