The largest database of trusted experimental protocols

Smart 1000 ccd area diffractometer

Manufactured by Bruker

The SMART 1000 CCD area diffractometer is a laboratory instrument designed for single-crystal X-ray diffraction analysis. It features a charge-coupled device (CCD) detector, providing high-resolution data collection capabilities for structural studies of crystalline materials.

Automatically generated - may contain errors

4 protocols using smart 1000 ccd area diffractometer

1

Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Starting materials, reagents and solvents with AR grade were purchased from commercial suppliers and used without further purification. Elemental analyses were performed on a Perkin-Elmer 240C elemental analyzer. IR spectra were recorded on a Jasco FT/IR-4000 spectrometer as KBr pellets in the 4000-400 cm -1 region. 1 (link) H NMR data were recorded on a Bruker 300 MHz instrument. X-ray diffraction was carried out on a Bruker SMART 1000 CCD area diffractometer.
+ Open protocol
+ Expand
2

Synthesis and Characterization of Copper(II) Azido Complexes

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solvents used were of AR grade and used as received. 4-Bromosalicyaldehyde, 2-(2-aminoethylamino) ethanol, copper acetate monohydrate, copper chloride dihydrate and sodium azide were purchased from Aladin Chemical Co. Ltd. and were used as received. Styrene, cyclooctene, cyclohexene and TBHP were purchased from Aldrich and were used as received. Infrared spectra (4000-400 cm -1 ) were recorded as KBr discs with a FTS-40 Bio-Rad FT-IR spectrophotometer. The electronic spectra were recorded on a Lambdar 35 spectrometer. Microanalyses (C, H, N) of the complex were carried out on a Carlo-Erba 1106 elemental analyzer. Solution electrical conductivity was measured at 298K using a DDS-11 conductivity meter. GC analyses were performed on a Shimadzu GC-2010 gas chromatograph. Crystallographic data of the complexes were collected on a Bruker SMART 1000 CCD area diffractometer with graphite monochromated Mo-Kα radiation (λ = 0.71073 Å) at 298(2) K.
Caution! Transition metal azido complexes are potentially explosive especially in the presence of organic ligands. Although we have not encountered any problem during our study, yet a small quantity of materials should be prepared and it should be handled with care.
+ Open protocol
+ Expand
3

Analytical Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Starting materials, reagents, and solvents of AR grade were purchased from commercial suppliers and used without further purification. Elemental analyzes were performed using a Perkin-Elmer 240C elemental analyzer. IR spectra were recorded as KBr pellets in the 4000-400 cm -1 range using a Jasco FT/IR-4000 spectrometer. 1 (link) H NMR data were recorded using a Bruker 300 MHz instrument and X-ray diffraction was performed with a Bruker SMART 1000 CCD area diffractometer.
+ Open protocol
+ Expand
4

Single Crystal X-Ray Diffraction Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data were collected on a Bruker SMART 1000 CCD area diffractometer using a graphite monochromator Mo Kα radiation (λ = 0.71073 Å) at 298(2) K. The data were corrected with SADABS programs and refined on F 2 with Siemens SHELXL software. 7 The structures were solved by direct methods and difference Fourier syntheses. All non-hydrogen atoms were refined anisotropically. The methanol hydrogen atoms were located from difference Fourier maps and refined isotropically, with O-H distances restrained to 0.85(1) Å. The remaining hydrogen atoms were placed in calculated positions and included in the last cycles of refinement. Crystal data and details of the data collection and refinement are listed in Table 1. Selected coordinate bond lengths and angles are listed in Table 2.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!