The largest database of trusted experimental protocols

Lc prominence lc20ad

Manufactured by Shimadzu

The Shimadzu Prominence LC20AD is a high-performance liquid chromatography (HPLC) system. It is designed to provide reliable and accurate analysis of a wide range of samples. The core function of the LC20AD is to separate, identify, and quantify the components within a liquid sample.

Automatically generated - may contain errors

2 protocols using lc prominence lc20ad

1

HPLC-MS/MS Quantification of Analytes

Check if the same lab product or an alternative is used in the 5 most similar protocols
The HPLC-MSMS system was composed of an LC-Shimadzu prominence LC20AD (Shimadzu Scientific Instruments, Columbia, MD) with an ultramino 3 μm 150 × 2.1 mm 100A aminopropylsilane Restek column (Restek, Bellefonte, PA) with a flow rate of 0.30 mL/min with degasser and autosampler SIL-20AC HT (Shimadzu Scientific Instruments) and column oven CTO-20A (Shimadzu Scientific Instruments) run at 40°C. Mobile phase A was HPLC-grade water with 0.1% formic acid, and phase B was acetonitrile with 0.1% formic acid. Elution was programmed to start at 70% phase B for 0.5 minute, then fall to 5% B at 2 minutes, return to 70%B at 2.5 minutes, and equilibrate for 2 minutes before the next sample injection.
MS/MS-API 5500 (AB Sciex, Framingham, MA) with turbo-ion probe (ESI) operated at 600°C. The transitions monitored are listed with the retention times in Appendix Table 2A.
+ Open protocol
+ Expand
2

Targeted Quantification of Analytes by HPLC-MS/MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
The HPLC-MSMS system was composed of a LC- Shimadzu prominence LC20AD (Shimadzu, Maryland), with an ultramino 3 um 150 x 2.1 mm 100A aminopropylsilaneRestek column (Restek, Bellafonte, PA) with a flow rate of 0.30 ml/min with degasser and auto-sampler SIL-20AC HT (Shimadzu, Maryland), and column oven CTO-20A (Shimadzu, MD) run at 40°C. Mobile phase A was HPLC grade water with 0.1% formic acid and phase B was acetonitrile with 0.1% formic acid. Elution was programmed to start at 70% phase B for 0.5 minutes, then fall to 5% B at 2 minutes, return to 70%B at 2.5 minutes and equilibrate for two minutes prior to the next sample injection. MS/MS-API 5500 (AB Sciex, US) with turbo-ion probe (ESI) operated at 600C. The transitions monitored described before are listed with the retention times in Table 1 [17 (link)].
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!