Lct premier xe ms

Manufactured by Waters Corporation
Sourced in United States

The LCT-premier XE MS is a high-performance liquid chromatography-time of flight mass spectrometry (LC-TOF MS) system designed for accurate mass measurement and high-resolution analysis. It provides precise quantitative and qualitative data for a wide range of applications.

Automatically generated - may contain errors

2 protocols using lct premier xe ms

1

Scalable Synthesis of PSG Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols
To produce sufficient quantities of the two PSG derivatives for the purpose of elucidating their chemical structure, multiple scale-up reactions were carried out as follows; the molar concentrations of PSs, UDP-Glc and MrSGT enzyme were maintained in the proportions described above, while scaling up the total volume of the reaction mixture to 1 mL. At the end of the reaction, reaction mixtures from more than five batches were pooled and extracted by ethyl acetate partitioning. The solvent layer obtained was evaporated to dryness using a centrifugal evaporator (EYELA, Tokyo, Japan) set at 40 °C, and reconstituted in 5 mL of the mobile phase used for the HPLC–MS/MS analyses. The extracts were immediately loaded onto a reverse-phase C8 cartridge of the CombiFlash Rf medium-pressure liquid chromatography (MPLC) system (Teledyne ISCO, Lincoln, NE, USA), and the flow rate was set at 8 mL/min. The eluents passing through a UV detector were all automatically fractionated over a 50-min running time. The fractions confirmed to contain the PSG derivative with a good purity (>97 %) by the tracing HPLC–MS/MS analyses, were pooled and freeze-dried. Their structures were further confirmed by Varian INOVA 500 nuclear magnetic resonance (NMR, Varian Inc., Palo Alto, CA, USA) spectroscopic analysis together with high resolution (HR) LCT-premier XE MS (Waters, Milford, MA, USA) analysis.
+ Open protocol
+ Expand
2

Phenoxodiol Glycoside Structural Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC-LCQ ion-trap MS/MS (ThermoFinnigan, USA) was performed using both acetonitrile:methanol:water:formic acid (40:40:19.8:0.2 v/v/v/v) mixture as isocratic mobile phase at a flow rate of 150 µl/min, and Acquity CSH C18 reversed-phase column (Waters, 50 × 1.0 mm, 1.7 µm; USA) as the stationary phase. The column effluent was introduced into the MS/MS operated in the positive ion mode. Acquisition was performed using MS/MS operated in the selective reaction monitoring mode by choosing a pair of mass transitions specific to phenoxodiol and the corresponding glycosides to detect the transition of the protonated precursor ion to the dominant product ion (241.2 [M+H]+ > 223.2 [M-H2O+H]+ as a dehydrated product ion for phenoxodiol and 403.4 > 241.2 [M-Glc+H]+ as an aglycone product ion for phenoxodiol glycoside). In addition, both high-resolution (HR) LCT-premier XE MS (Waters) and Varian INOVA 500 nuclear magnetic resonance (NMR, Varian Inc., USA) were employed for the structural elucidation of two kinds of phenoxodiol glycosides.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!