The largest database of trusted experimental protocols

Falling number 1500

Manufactured by PerkinElmer
Sourced in Sweden

The Falling Number 1500 is a laboratory instrument designed to measure the falling number, a parameter used to assess the quality and baking performance of wheat and other cereal grains. The instrument measures the time it takes for a plunger to fall through a heated water and flour slurry, providing an indication of the alpha-amylase activity in the sample.

Automatically generated - may contain errors

3 protocols using falling number 1500

1

Physicochemical and Rheological Profiling of Durum Wheat Flour

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ash content was obtained following the ISO method 2171 (2007). The gluten index was determined using a Glutomatic 2200 apparatus (Perten Instruments AB, Huddinge, Sweden) according to the method UNI 10690 (1979). The α-amylase activity was determined using the Falling Number 1500 apparatus (Perten Instruments AB, Huddinge, Sweden), following the method UNI EN ISO 3093 (2010).
Total, soluble and insoluble dietary fiber content was determined using a K-TDFR kit from Megazyme (Megazyme International, Bray, Ireland) (29 ). The protein content and color indexes were determined according to the methods described for durum wheat whole flour (30 ).
Rheological dough properties were evaluated by mixograph (National Mfg. Co, Nebraska, USA) and farinograph curves (Brabender instrument, Duisburg, Germany) (31 (link)). All the analyses were conducted in triplicate.
+ Open protocol
+ Expand
2

Flour Amylograph and Falling Number Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The falling number test (FN) was determined using a Falling Number 1500 apparatus (Perten Instruments, Hägersten, Stockholm, Sweden) according to Standard ISO 3093:2009 [19 ], and the amylograph test was determined using an amylograph type 800145 with electronic temperature controller type 680026 (Brabender, Duisburg, Germany) according to Standard ISO 7973:1992 [20 ]. For the amylograph test, a suspension of 80 g of flour (based on 14% water content) and 450 cm3 distilled water was made.
+ Open protocol
+ Expand
3

Wheat Flour Quality Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
The farinograph indices were determined according to the AACC 54–21 method [26 ] by a farinograph (Brabender instrument, Duisburg, Germany), equipped with the software farinograph (Brabender instrument, Duisburg, Germany). Alveograph trials were performed according to the AACC method 54–30A [24 ] using an alveoconsistograph, equipped with the software Alveolink NG (Tripette et Renaud, Villeneuve-la-Garenne, France). The α-amylase activity was determined by using the Falling Number 1500 apparatus (Perten Instruments AB, Huddinge, Sweden), according to the ISO 3093:2009 method [31 ]. Rheofermentometer analysis (F3 rheofermentometer, Tripette et Renaud, Chopin Technologies, Villeneuve-la-Garenne, France) was carried out according to the AACC 89-01 method [26 ] at 28.5 °C for 3 h, with a 2000 g weight. All analyses were carried out in triplicate.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!