Orbitrap velos pro system

Manufactured by Thermo Fisher Scientific
Sourced in United States

The Orbitrap Velos Pro system is a high-performance mass spectrometer designed for advanced analytical applications. It utilizes the Orbitrap mass analyzer, which provides high-resolution, accurate mass measurements. The system is capable of performing various mass spectrometry techniques, including full-scan, targeted, and data-dependent acquisition modes.

Automatically generated - may contain errors

2 protocols using orbitrap velos pro system

1

Comprehensive UHPLC-Orbitrap Metabolomics Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
A UHPLC system equipped with a Vanquish binary pump H system (Thermo Fisher Scientific, Waltham, MA, USA) was united with an auto-sampler and column compartment. A Phenomenex KINETEX® C18 column (100 mm × 2.1 mm, 1.7 µm particle size; Torrance, CA, USA) was used to chromatographic separation. The injection volume was 5 µL. The column temperature was set to 40 °C, and the flow rate was 0.3 mL/min. The mobile phase consisted of 0.1% v/v formic acid in water (A) and acetonitrile (B). The gradient parameters were configured as follows: Five percent solvent B was maintained initially for 1 min, followed by a linear increase to 100% solvent B over 9 min and then sustained at 100% solvent B for 1 min, with a gradual decrease to 5% solvent B over 3 min. The total run time was 14 min. The MS data were collected in a range of 100–1500 m/z (in negative- and positive-ion mode) using an Orbitrap Velos Pro system (Thermo Fisher Scientific, Waltham, MA, USA) coupled with an ion-trap mass spectrometer coupled with a heated electrospray ionization (HESI-II) probe. The probe heater and capillary temperatures were set to 300 °C and 350 °C, respectively. The capillary voltage was set to 2.5 kV in negative mode (positive mode 3.7 kV).
+ Open protocol
+ Expand
2

UHPLC-Orbitrap-MS/MS Analysis of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The dried extracts were re-dissolved in 80% MeOH for UHPLC-LTQ-Orbitrap-MS/MS analysis. All analytes were set to 20,000 ppm by using daidzein (0.25 mg/ml) as IS.
A UHPLC system was equipped with a Vanquish binary pump H system (Thermo Fisher Scientific, Waltham, MA, USA) coupled with an autosampler and column compartment. Chromatographic separation was performed with a Phenomenex KINETEX® C18 column (100 mm × 2.1 mm, 1.7 μm particle size; Torrance, CA, USA); and the injection volume was 5 μl. The column temperature was set at 40°C, and the flow rate was 0.3 ml/min. The MS data were collected in the range of 100–1,500 m/z (under both negative- and positive-ion modes) using an Orbitrap Velos Pro™ system, which was combined with an ion-trap mass spectrometer (Thermo Fisher Scientific) coupled with a HESI-II probe. All samples were analyzed based on the analytical methods described by Kwon et al. (20 (link)).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!