2 protocols using anti mouse cd40 clone fgk4.5 gfk45

1

Biocompatibility Anchors for Cell Membranes

Check if the same lab product or an alternative is used in the 5 most similar protocols
The Biocompatibility Anchors for Cell Membranes (BAM) were acquired from NOF America (White Plains, NY). Mannan from Saccharomyces cerevisiae, polyinosinic-polycytidylic acid sodium salt, and lipoteichoic acid from Bacillus subtilis were obtained from Sigma-Aldrich (St. Louis, MO). Resiquimod (R-848) was purchased from Tocris Bioscience (Minneapolis, MN). Anti-mouse CD40 (clone: FGK4.5/GFK45) was procured from BioXCell (West Lebanon, NH). Flow cytometry antibodies, including anti-CD4, anti-CD8, anti-CD11c, anti-IFN-γ, anti-CD44, anti-CD62L, anti-Ly6G, anti-Ly6C, anti-CD11b were obtained from BD biosciences (Franklin Lakes, NJ); anti-CD45, anti-CD107a, anti-CD80, anti-CD86, anti-CD137L, anti-MHCII, anti-TNF-α, anti-CD19, anti-MHCII, anti-TCRβ and anti-GranB were obtained from Bioligand (San Diego, CA). The ELISA kits for detecting IFN-γ, TNF-α, and IL-6 were obtained from Bioligand (San Diego, CA).
+ Open protocol
+ Expand
2

Synthesis of Mannan-BAM Conjugate

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mannan and polyinosinic–polycytidylic acid sodium salt were obtained from Sigma-Aldrich (St. Louis, Mo). Lipoteichoic acid was obtained from Sigma-Aldrich (St. Louis, Mo) and InvivoGen (San Diego, CA). Resiquimod was obtained from Tocris Bioscience (Minneapolis MN). Anti-mouse CD40 (clone: FGK4.5/GFK45) was obtained from BioXCell (West Lebanon, NH). Biocompatible anchor for cell membrane (BAM) was obtained from NOF America Corporation (White Plains, NY).
Mannan-BAM synthesis was performed as previously reported.[9 (link),11 (link),14 (link)] Aminated Mannan was prepared by reductive amination.[42 (link)] Mannan solution in an environment of ammonium acetate (300 mg ml−1) was reduced by 0.2 M sodium cyanoborohydride at pH 7.5 and 50 °C for five days. Solution was further dialyzed using MWCO 3500 dialysis tubing (Serva, Heidelberg, Germany) against PBS at 4 °C overnight. Binding of BAM on amino group of Mannan was performed at pH 7.3 according to Kato et al.[10 (link)] During one hour at room temperature N-hydroxysuccinimide (NHS) group of BAM reacted with amino group of Mannan. Solutions obtained after dialysis as above was stored frozen at −20 0C until use.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!