The largest database of trusted experimental protocols

Cobas 8000 analyzer e602 module

Manufactured by Roche
Sourced in Germany

The Cobas 8000 analyzer e602 module is a laboratory equipment designed for clinical chemistry testing. It is capable of performing various types of immunoassay analyses. The e602 module is part of the Cobas 8000 series of analyzers, which are intended for in-vitro diagnostic use in clinical laboratories.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using cobas 8000 analyzer e602 module

1

Thyroid Hormone Profile Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
The levels of free triiodothyronine (FT3) (reference range, 3.1–6.8 pmol/L), free thyroxine (FT4) (reference range, 12.0–22.0 pmol/L), thyroid stimulating hormone (TSH) (reference range, 0.270–4.20 mIU/L), thyroglobulin antibody (TGAb) (cut-off level, 115 IU/mL), thyroid peroxidase antibody (TPOAb) (cut-off level, 34 IU/mL), and TSH receptor antibody (TRAb) (cut-off level, 1.75 IU/L) were measured automatically by Cobas c8000 machine via utilizing a commercial electro-chemiluminescence immunoassay kit (Roche Diagnostics, Cobas 8000 analyzer e602 module). The intra-assay CVs of FT3, FT4, TSH, TGAb, TPOAb, and TRAb were 1.4–6.5%, 2.6–4.3%, 1.1–3.0%, 1.3–4.9%, 2.7–6.3%, and 0.9–7.6%, respectively, and the inter-assay CVs of coefficients of these indexes were 1.9–7.2%, 5.1–8.4%, 3.3–7.2%, 3.4–6.3%, 4.2–9.5%, and 1.9–11.4%, respectively.
+ Open protocol
+ Expand
2

Thyroid Function Biomarker Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Thyroxine and TSH concentrations were measured using electrochemiluminescence immunoassay (ECLIA) kit provided by Roche Diagnostics (Cobas 8000 Analyzer e602 module, Germany) following the manufacturer's instructions. Anti-TPO and anti-Tg antibodies were also determined using an ECLIA kit provided by Roche Diagnostics, cutoff values for abnormal levels were set at 34 IU/mL and 115 IU/ mL respectively.
+ Open protocol
+ Expand
3

Thyroid Hormone and Antibody Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
The levels of free thyroxine (FT4) (reference range, 12-22 pmol/L), TSH (reference range, 0.27-4.2 mIU/L), TpoAb (cut-off level, 34 IU/mL), and TgAb (cut-off level, 115 IU/mL) were determined in all the subjects on the same day of sampling, utilizing a commercial electrochemiluminescence immunoassay kit (Roche Diagnostics, Cobas 8000 analyzer e602 module, Germany). The intra-assay CVs of TSH, FT4, TpoAb, and TgAb were 1.73% to 2.44%, 1.73% to 2.51%, 4.07% to 7.13%, and 4.20% to 6.60%, respectively. The inter-assay CVs of TSH, FT4, TpoAb, and TgAb were 2.05% to 4.12%, 2.11% to 2.57%, 5.04% to 8.49%, and 5.33% to 7.22%, respectively.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.