The largest database of trusted experimental protocols

2 protocols using rat anti e cadherin

1

Whole-Mount Immunohistochemistry for Tissue Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Whole-mount immunohistochemistry was performed using a modification of
the protocol from Ahnfelt-Rønne et al.
(2007)
as previously described (Havrilak and Shannon, 2015b (link)). Optical sections were captured on a
Nikon AiRsi inverted laser microscope, and 3D images were created by a composite
of z-stacks using Bitplane Imaris software to process the fluorescent images. To
calculate the volume of tissue stained for ALB, we created isosurfaces using
smoothing thresholds and intensity values that allowed filtering out antibody
aggregates or any non-specific staining.
The primary antibodies used were: rabbit anti-NKX2-1 (1:3000, Seven
Hills Bioreagents), guinea pig anti-NKX2-1 (1:500, Seven Hills Bioreagents),
goat anti-endomucin (1:500, R & D Systems), rat anti-E-cadherin (1:2000,
R & D Systems), rabbit anti-PAX8 (1:500, Protein Tech), rat anti-PECAM-1
(1:500, BD Pharmigen), goat anti-HNF4α (1:200, Santa Cruz), goat
anti-PDX1 (1:5000, Abcam), goat anti-ALB (1:1000, Bethyl Laboratories), goat
anti-FOXA2 (1:500, Santa Cruz), and rat anti-LIV2 (1:200, MBL). Secondary
antibodies used were: Alexa Fluor 647 donkey anti-rabbit IgG, Alexa Fluor 568
anti-goat IgG, Alexa Fluor 488 donkey anti-rat IgG, Alexa Fluor 488 donkey
antimouse IgG (1:500, all from Life Technologies).
+ Open protocol
+ Expand
2

Whole-Mount Immunohistochemistry for Tissue Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Whole-mount immunohistochemistry was performed using a modification of
the protocol from Ahnfelt-Rønne et al.
(2007)
as previously described (Havrilak and Shannon, 2015b (link)). Optical sections were captured on a
Nikon AiRsi inverted laser microscope, and 3D images were created by a composite
of z-stacks using Bitplane Imaris software to process the fluorescent images. To
calculate the volume of tissue stained for ALB, we created isosurfaces using
smoothing thresholds and intensity values that allowed filtering out antibody
aggregates or any non-specific staining.
The primary antibodies used were: rabbit anti-NKX2-1 (1:3000, Seven
Hills Bioreagents), guinea pig anti-NKX2-1 (1:500, Seven Hills Bioreagents),
goat anti-endomucin (1:500, R & D Systems), rat anti-E-cadherin (1:2000,
R & D Systems), rabbit anti-PAX8 (1:500, Protein Tech), rat anti-PECAM-1
(1:500, BD Pharmigen), goat anti-HNF4α (1:200, Santa Cruz), goat
anti-PDX1 (1:5000, Abcam), goat anti-ALB (1:1000, Bethyl Laboratories), goat
anti-FOXA2 (1:500, Santa Cruz), and rat anti-LIV2 (1:200, MBL). Secondary
antibodies used were: Alexa Fluor 647 donkey anti-rabbit IgG, Alexa Fluor 568
anti-goat IgG, Alexa Fluor 488 donkey anti-rat IgG, Alexa Fluor 488 donkey
antimouse IgG (1:500, all from Life Technologies).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!