4 protocols using av 600 nmr spectrometers

1

Spectroscopic and Chromatographic Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
The UV spectra were conducted on a UV-2201 spectrometer (Shimadzu, Kyoto, Japan). The FT-IR spectra were obtained on a Bruker IFS-55 spectrometer (Bruker, Ettlingen, Germany) by a KBr disk method. ESI-MS spectra were conducted on an Agilent 1100 ion trap spectrometer (Agilent Technologies, Palo Alto, CA, USA). HRESI-MS was recorded on a QFT-ESI mass spectrometer (Varian, Palo Alto, CA, USA). 1H-NMR and 13C-NMR spectra were recorded on Bruker ARX-300 and AV-600 NMR spectrometers (Bruker, Ettlingen, Germany) using pyridine-d5 as an internal standard [δH/C 7.20, 7.57, 8.72/123.44, 135.43, 149.84 (C5D5N)]. Optical rotations were measured with a Perkin-Elmer 241 polarimeter (Perkin-Elmer, Boston, MA, USA). The chromatographic silica gel (200−300 mesh) was purchased from Qingdao Ocean Chemical Factory (Qingdao, China) and ODS (50 μm) was purchased from YMC Co. Ltd, Kyoto, Japan. Sephadex LH-20 was purchased from GE Healthcare, Uppsala, Sweden. RP-HPLC analysis and semi-preparation were conducted using HITACHI L2130 series pumping system equipped with a HITACHI L2400 UV detector (Tokyo, Japan) and performed with a C-18 column (10 × 250 mm, 10 μm; YMC Co. Ltd, Kyoto, Japan).
+ Open protocol
+ Expand
2

Comprehensive Analytical Techniques for Natural Product Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were recorded on an Anton Paar MCP 200 polarimeter. UV spectra were measured on a Shimadzu UV-2201 spectrometer. ECD spectra were obtained on a Bio-Logic MOS 450 spectrometer. IR spectra were measured on a Bruker IFS-55 spectrometer. 1D and 2D NMR spectra were acquired on Bruker AV-400 or AV-600 NMR spectrometers. Mass spectra were measured on Bruker micrOTOFQ-Q mass spectrometer. Single-crystal X-ray diffraction data was collected on a Rigaku Saturn 724 CCD diffractometer. Column chromatography (CC) were performed with D101 macroporous adsorption resin (D101 MAR), silica gel, ODS, and Sephadex LH-20. Semipreparative HPLC was performed with YMC ODS column, and the HPLC system was equipped with a Shimadzu SPD-20A UV–vis detector and LC-6AD pump.
+ Open protocol
+ Expand
3

Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were performed on a PerkinElmer model 341 polarimeter. The UV spectra were obtained with a JASCO V-730BIO spectrophotometer. The ECD spectra were carried out on a Bio-Logic Science MOS-450 circular dichroism spectrometer. The IR spectra were run on a JASCO FT/IR-4100 Fourier transform infrared spectrometer using the KBr disk method. The NMR spectra were recorded on Bruker AV-600 NMR spectrometers with the deuterated solvent used as the internal reference (1H NMR residual proton signal: methanol-d4 δ 3.31; 13C NMR methanol-d4 δ 49.0). The 1H NMR spectra were run at 600 MHz, and the 13C NMR spectra were produced at 150 MHz. Chemical shifts were expressed in δ (ppm) and reported as s (singlet), d (doublet), t (triplet), dd (doublet of doublets), dt (doublet of triplets), td (triplet of doublets), br (broad), and m (multiplet), respectively. HRESIMS were measured on a Q-Exactive Hybrid Quadrupole Orbitrap mass spectrometer. Column chromatography was performed with D101 macroporous resin (Hebei Cangzhou Baoen Chemical Co., Ltd.), silica gel (Qingdao Marine Chemical Co., Ltd.), and ODS (50 μm, YMC Co., Ltd.). Preparative HPLC was conducted on a YMC ODS column (5 μm, 10 mm × 250 mm) with an LC-10AD pump system and an SPD-20A UV detector (Shimadzu).
+ Open protocol
+ Expand
4

Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The optical rotation was carried out in MeOH using a Anton Paar polarimeter with a 1 cm cell at 20°C. UV spectrum (MeOH) was obtained with a Shimadzu UV-1700.
NMR spectra were recorded in CDCl 3 on Bruker ARX-400 or AV-600 NMR spectrometers, with tetramethylsilane as the internal standard. HR-ESI-MS was measured on a Bruker micrOTOF-Q mass spectrometer. CD spectrum was measured on a JASCO CD-2095 Chiral Detector.Semi-preparative HPLC was performed on a YMC ODS-A column (250 × 20mm I.D., 5 µm) equipped with a LC-6AD pump and a Shimadzu SPD-20A UV-Vis detector (Shimadzu Co., Ltd., Japan). Silica gel (Qingdao Haiyang Chemical Group Co.; 200-300 mesh), neutral alumina (100-200 mesh, Sinopharm Chemical Reagent Co. Ltd., Shanghai, People's Republic of China), ODS (50µm, YMC Co. Ltd., Kyoto, Japan), 0017 ion-exchange resin (Dianli Resin Co. Ltd., Langfang, People's Republic of China) and Sephadex LH-20 (GE Healthcare, Sweden) were used for column chromatography.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!