The largest database of trusted experimental protocols

12 protocols using didodecyldimethylammonium bromide

1

Lipid-Based Nanocarrier Formulation

Check if the same lab product or an alternative is used in the 5 most similar protocols
L-α-phosphatidylcholine from egg yolk (EPC), cholesterol (Ch), didodecyldimethylammonium bromide (DDAB), and cholesteryl hemisuccinate (Chems) were provided by Sigma–Aldrich (Barcelone, Spain). Stearylamine (SA) was purchased from Fluka (Munich, Germany). Timolol maleate (TM), acetazolamide (Acz), and dodecylsulfate were purchased from Acofarma (Barcelone, Spain). (2-hydroxy)propyl-β-cyclodextrin (HPβCD, Eur. Pharm. 5th ed., D.S. 6.3) was supplied by Roquette (Lestrem, France). Acetonitrile (ACN), trichloromethane, methanol, ethanol, and 2-[4-(2-hydroxyethyl)-1-piperazinyl] ethanesulfonic acid (Hepes) were obtained from Panreac Química (Barcelone, Spain). Polycarbonate membranes (800 and 200 nm in pore size) were acquired from Millipore (Dublin, County Cork, Ireland). All other chemicals used were of analytical degree.
+ Open protocol
+ Expand
2

Fabrication and Characterization of Curcumin-Loaded PLGA Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Bovine serum albumin (BSA), cholesterol, curcumin, dicetyl phosphate (DCP), 2,6-dichloroindophenol (DCIP), didodecyldimethylammonium bromide (DMAB), phosphatidylethanolamine (PE), poly(d,l-lactide-co-glycolide) (PLGA) (Resomer RG 85:15H), phenazine methosulfate (PMS), and succinic acid were purchased from Sigma-Aldrich (St Louis, MO, USA). CM-H2DCFDA was obtained from Thermo Fisher Scientific (Waltham, MA, USA). Ethyl acetate (AR grade) was procured from Rankem Fine Chemicals (New Delhi, India). Chloroform and methanol were purchased from E Merck (Darmstadt, Germany). All other reagents were of analytical grade.
+ Open protocol
+ Expand
3

Glimepiride-loaded PLGA Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Glimepiride was kindly supplied by Spimaco Addwaeih, Riyadh, Saudi Arabia. Zein, PLGA (50:50, molecular weight of 38,000–54,000 g/mol), ethanol, methanol, dichloromethane (DCM), sodium lauryl sulfate (SLS), didodecyldimethylammonium bromide (DDAB), stannous 2-ethylhexanoate, PEG 1500, and N-methyl-2-pyrrolidone (NMP) were purchased from Sigma Aldrich Corporation, St Louis, MO, USA. All other chemicals were of analytical grade and were used as received.
+ Open protocol
+ Expand
4

Cellulose Derivatives and Cationic Surfactant Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The cellulose derivatives carboxymethylcellulose, CMC (degree of substitution of 0.65–0.90; viscosity of a 1% aqueous solution is 1500–3000 cps), and quaternized hydroxyethylcellulose ethoxylate, QHECE, (viscosity of a 1% aqueous solution is 300–500 cps), the cationic surfactant didodecyldimethylammonium bromide, DDAB (purity of 98%), NaOH (≥98%), and HCl (30%) were purchased from Sigma-Aldrich. Deionized water was used in the preparation of all solutions.
+ Open protocol
+ Expand
5

Synthesis and Characterization of Inorganic Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Acetone (≥99.5%, Sigma-Aldrich), ammonium persulfate (≥98.0% Sigma-Aldrich), chlorobenzene (99.9%, Sigma-Aldrich), didodecyldimethylammonium bromide (98.0%, Sigma-Aldrich), 1-dodecanethiol (98.0%, ACROS Organics), 1,2-ethanedithiol (≥98.0%, Sigma-Aldrich), hydrochloric acid (37.0%, VWR Chemicals), mercury(ii) chloride (≥99.5%, Sigma-Aldrich), methanol (≥99.9%, Sigma-Aldrich), methyl-iso-butyl ketone (MIBK; 99.8%, VWR Chemicals), oleylamine (>95.0%, Strem Chemicals), tellurium (99.999%, Sigma-Aldrich), anhydrous tetrachloroethylene (≥99.0%, Sigma-Aldrich), tri-n-octylphosphine (97.0%, STREM), 50 K PMMA (4.0% in anisole, Allresist), 950 K PMMA (4.5% in anisole, Allresist) and 2-propanol (≥99.8%, Sigma-Aldrich).
All the chemicals were used as received, unless otherwise stated. oleylamine was dried and degassed under reduced pressure at a temperature of 120 °C for 1 h before its use.
Trioctylphosphine telluride (TOP:Te) was synthesized by stirring 5.08 g tellurium (0.04 mol) in dry trioctylphosphine (20 ml) for three days yielding a 2 M TOP:Te solution. The solution was filtered through a 0.45 μm polytetrafluoroethylene syringe filter resulting in a clear, yellowish solution.
Cleanroom: 21.5 °C; 45–50% relative humidity; particle class, 10–10,000; >18 MΩ cm purified water.
+ Open protocol
+ Expand
6

Synthesis of Perovskite Solar Cell Materials

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cesium carbonate (99.9%), Cadmium acetate dihydrate (reagent grade 98%), Zinc acetate dihydrate (99.999% trace metals basis), Mercury acetate (ACS reagent ≥98.0%) 1‐octadecene (ODE; 90% tech.), Oleylamine (OAm; 70% tech.), Oleic acid (OA; 90% tech.), Methyl acetate (MeOAc; anhydrous 99.5%), Octane (anhydrous ≥99%), Toluene (anhydrous 99.8%), Hexane (anhydrous 95%), Chlorobenzene (anhydrous 99.8%), Lead bromide (PbBr2; 99.999% trace metal basis), poly[(9,9‐dioctylfluorenyl‐2,7‐diyl)‐co‐(4,4′‐(N‐(4‐sec‐butyl phenyl)diphenylamine)] (TFB) and Didodecyldimethylammonium bromide (DDAB; 98%) and sodium fluoride (NaF; BioXtra, ≥99%) were purchased from Sigma Aldrich. Poly[bis(4‐phenyl)(2,4,6‐trimethylphenyl)amine (PTAA; Mw: 30 000) was purchased from Ossila. Indium tin oxide‐based transparent conductive electrode (≈4.5 Ω sq−1) purchased from AMG. MoO3 (99.9995%) was purchased from Alfa Aesar. Aqueous solution of PEDOT: PSS (Clevios AI 4083) purchased from Heraeus. 2,2′,2″‐(1,3,5‐benzinetriyl)tris(1‐phenyl‐1‐H‐benzimidazole) (TPBi; 99.9%) was purchased from OSM. LiF (99.9%), Ag (99.99%), and Al (99.9%) were purchased from iTASCO.
+ Open protocol
+ Expand
7

Synthesis of Cesium Lead Bromide Perovskite Nanocrystals

Check if the same lab product or an alternative is used in the 5 most similar protocols
CsCO3 (99.9%), octadecene (ODE;
for synthesis), oleic acid (OA; technical grade, 70%), PbBr2 (99.999%), oleylamine (OLA; technical grade, 70%), toluene (99.8%),
hexane (95%), and di-dodecyl dimethyl ammonium bromide (DDAB; 98%)
were purchased from Sigma-Aldrich. ODE, OA, and OLA were degassed
at 120 °C before any reaction.
+ Open protocol
+ Expand
8

Lipid-Based Formulations for Drug Delivery

Check if the same lab product or an alternative is used in the 5 most similar protocols
Labrafac ® Lipophile WL 1349 (MCT), mixture of mediumchain triglycerides of caprylic and capric acids, was kindly provided by Gattefossé. Capmul ® MCM EP/NF (MCM), mixture of mono-and di-glycerides of caprylic and capric acids, was kindly provided by Abitec. Kolliphor® HS 15 (polyethylene glycol (15)-hydroxystearate-HS15), Kolliphor ® EL (polyoxyl-35 castor oil-EL35), propylene glycol (PG), didodecyldimethylammonium bromide (DDA), sodium deoxycholate (DEO), sterile Dulbecco's phosphate buffered saline pH 7.4 (PBS), fluorescein isothiocyanate isomer I (FITC) and pyrene were purchased from Sigma Aldrich, Austria. Sephacryl ® S400-HR suspension (in 20% aqueous ethanol) with particle size 25-75 μm in wet state and fractionation range of globular proteins 2 × 10 4 -8 × 10 6 was purchased from Sigma Aldrich, Austria. Micro BCA™ protein assay kit was purchased from Thermo Fisher Scientific, Austria. Human whole blood and frozen human plasma were kindly donated by the Blutbank, Tirol Kliniken GmbH, Innsbruck, Tirol, Austria. During whole blood donation, the anticoagulant solution CPD (citrate-phosphate-dextrose) was used to prevent clotting and maintain the shelf life of the blood products.
+ Open protocol
+ Expand
9

Synthesis of Perovskite Nanocrystals

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cadmium acetate dihydrate ((CdAc2·2H2O), 99.99%), lead acetate trihydrate ((PbAc2·3H2O), 99.99%), cesium carbonate (Cs2CO3, reagent Plus, 99%), benzoyl bromide (C6H5COBr, 97%), ethyl acetate (98.8%), toluene (anhydrous,
99.5%), phenethylammonium bromide (≥98%), didodecyldimethylammonium
bromide (DDABr), octadecene (ODE, technical grade, 90%), dimethyl sulfoxide-d6 (DMSO, 99 atom % D) toluene-d8 (99 atom % D), and oleic acid (OA,
90%) were purchased from Sigma-Aldrich. Indium tin oxide (ITO)-patterned
substrates, polystyrene sulfonate (PEDOT:PSS, AL 4083), poly(N,N9-bis(4-butylphenyl)-N,N9-bis(phenyl)-benzidine) (poly-TPD), and 2,2′,2″-(1,3,5-benzinetriyl)-tris(1-phenyl-1-H-benzimidazole) (TPBi) were purchased from Ossila Ltd.
Poly(9-vinylcarbazole) (PVK) and LiF were purchased from Sigma-Aldrich.
Didodecylamine (97%) was purchased from TCI. oleic acid was dried
at 120 °C for an hour and stored in a nitrogen-filled glove box.
All other chemicals were used without further purification.
+ Open protocol
+ Expand
10

Colloidal Lead Halide Perovskite Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lead(II) acetate trihydrate (Pb(CH3COO)2·3H2O, 99.99%), cesium carbonate
(Cs2CO3, 99%), benzoyl bromide (97%), 1-octadecene
(ODE, 90%), anhydrous ethyl acetate (99.8%), anhydrous acetone, toluene
(≥99.7%), deuterated toluene (toluene-d8, 99.8 at. % D), deuterated dimethyl sulfoxide (d-DMSO, 99.9
atom. % D), oleic acid (OA, 90%), didodecyldimethylammonium
bromide (DDABr, 98%), 1-octylamine (99%), dioctylamine (98%), trioctylamine
(98%), 1-octanal (99%), dioctyl sulfide (96%), 1-octanoic acid (%),
10-undecenoic acid (98%), diisooctylphosphinic acid (90%), 1-octylphosphonic
acid (99%), 1-octanol (99%), and 1-octanethiol (98.5%) were purchased
from Sigma. Didodecylamine (DDA, 97%) and 9-heptadecanone (98%) were
purchased from TCI Chemicals. Trioctylphosphine (TOP, 97%) and Trioctylphosphine
oxide (99%, TOPO) were purchased from Strem Chemicals. All chemicals
were used without further purification.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!