The largest database of trusted experimental protocols

Chiralcel oj h column

Manufactured by Daicel
Sourced in Japan

The Chiralcel OJ-H column is a type of chromatography column used for the separation and purification of enantiomers. It is a high-performance liquid chromatography (HPLC) column that utilizes a chiral stationary phase to selectively retain and separate the different optical isomers of a compound.

Automatically generated - may contain errors

6 protocols using chiralcel oj h column

1

Enantioselective Synthesis of Chiral Ester

Check if the same lab product or an alternative is used in the 5 most similar protocols
[α]D20 = −21.5 (c 0.14,
CH2Cl2). 1H NMR (400 MHz, CDCl3) δ 7.38–7.31
(m, 2H), 7.07–6.99 (m, 2H), 5.14–5.06 (m, 1H), 4.18
(q, J = 7.1 Hz, 2H), 3.39 (d, J =
2.6 Hz, 1H), 2.76–2.64 (m, 2H), 1.26 (t, J = 7.1 Hz, 3H). 13C NMR (100 MHz, CDCl3) δ
172.3, 162.3 (d, J = 244 Hz), 138.3, 127.4, 115.3,
69.7, 60.9, 43.3, 14.1. The enantiomeric excess was determined by
HPLC using the Daicel Chiralcel OJ-H column, hexane/i-PrOH 99:1, flow rate 1.0 mL/min, UV detection at 220 nm, tminor = 57.433 min, tmajor = 59.097 min, 82% ee.
+ Open protocol
+ Expand
2

Stereoselective CYP3201B1 Biotransformation

Check if the same lab product or an alternative is used in the 5 most similar protocols
A 400‐μL reaction mixture containing 500 nm of CYP3201B1, 50 mm KPB (pH 6.0), 2 mm NADPH, and 1 mm PAN was incubated at 20 °C for 10 min. The reaction was started by the addition of NADPH. Reaction products were extracted using 600 μL of n‐hexane:2‐propanol (85 : 15) and analysed using a Prominence UFLC Liquid Chromatography System (Shimadzu) equipped with a CHIRALCEL OJ‐H column (250 mm × 4.6 mm i.d.; Daicel Corporation, Tokyo, Japan) under the following conditions: Column oven temperature of 30 °C, solvent of n‐hexane:2‐propanol (85 : 15) and flow rate of 1.0 mL·min−1.
+ Open protocol
+ Expand
3

Chiral HPLC Analysis of ZPF Stereoisomers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chiral HPLC analysis was carried out on an Agilent HP 1100 HPLC using a Chiralcel OJ-H column (4.6 mm × 150 mm, 5 µm, Daicel Corp., Tokyo, Japan). The mobile phase, hexane-isopropanol-triflouroacetic acid (90:10:0.1, v/v/v), was filtered (0.45 µm), degassed, and delivered at a flow rate of 0.8 ml/min. The column temperature was maintained at 25 °C, and the injection volume was 20 µl. (RS)-ZPF, (R)-ZPF, and (S)-ZPF were detected at 240 nm.
+ Open protocol
+ Expand
4

HPLC-based Determination of Reaction Conversion and Enantiomeric Excess

Check if the same lab product or an alternative is used in the 5 most similar protocols
The reactions were terminated by adding acetonitrile. Subsequently, the supernatant was filtered via 0.22 μm filtration after the high‐speed centrifugation (13,000 rpm, 10 min). The samples were analyzed by using the HPLC [Cosmosil‐C18, flow rate: 1ml/min, column temperature: 28°C, UV detection wavelength: 280 nm, mobile phase: isocratic elution with acetonitrile (A): water (B)‐60:40(v/v)]. The conversion rate was determined as the product concentration /(substrate concentration)/100%. The product concentration or substrate concentration was calculated from the standard curve. Values were expressed as the means ± SD (n = 3).
The e.e values were analyzed by using the chiral HPLC that was connected to a CHIRALCEL OJ‐H column (Daicel Chemical Industries, Ltd., Tokyo, Japan). The mobile phase was n‐hexane: ethanol‐60:40 (v/v). The e.e values were determined with the formula 100%*(S‐R)/(S + R).
+ Open protocol
+ Expand
5

Analytical Methods for Chiral Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
GC analyses were performed on a 7890A GC system (Agilent), equipped with an FID detector. HPLC analyses were carried on a 1100A HPLC system (Agilent), equipped with an VWD detector. The product yield and ee value of (R)-levodione were determined by GC using a CP-ChiraSil-DEX CB column (25 m × 0.25 mm × 0.25 μm, Agilent) as described previously.3,11 (link) The product yield and de value of dihydrocarvone were determined by GC using a DB-5 column (30 m × 0.32 mm × 0.25 μm, Agilent) as described previously.3 (link) The yield and ee value of 2-methyl-hydrocinnamaldehyde (12b) was determined by HPLC using a Chiralcel OJ-H column (250 mm × 4.6 mm, Daicel, Shanghai, China) as described previously.11 (link) The conversion of citral (12a) was performed on GC using a HP-5 column (30 m × 0.32 mm × 0.25 μm, Agilent) as described previously.3 (link) The ee value of citronellal was determined by GC using a Beta DEX 225 column (30 m × 0.25 mm × 0.25 μm, Supelco, Bellafonte, PA, USA) as described previously.3 (link)
+ Open protocol
+ Expand
6

Enantiopurification of Racemate by SFC

Check if the same lab product or an alternative is used in the 5 most similar protocols
S006-830
racemate was synthesized as described earlier4 (link) (Supporting Information, Figure S1).
The enantiomers were purified by supercritical fluid chromatography
on a chiral column (Chiralcel OJ-H column, Daicel Corp., Japan). The
optimized protocol comprised a mobile phase of 0.5% isopropanol in
methanol, with a flow rate of 2.5 mL/min, temperature of 35 °C,
and detection wavelength of 233 nm.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!