10 protocols using isco combiflash rf

1

Analytical Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR data were collected using a JEOL ECA-500 NMR spectrometer operating at 500 MHz for 1H and 125 MHz for 13C (JEOL Ltd., Tokyo, Japan). Residual solvent signals were utilized for referencing. High resolution mass spectra (HRMS) were obtained using a Thermo LTQ Orbitrap XL mass spectrometer equipped with an electrospray ionization source (Thermo Fisher Scientific, San Jose, CA, USA). Phenomenex Gemini-NX C18 analytical (5 μm; 250 × 4.6 mm) and preparative (5 μm; 250 × 21.2 mm) columns (Phenomenex, Torrance, CA, USA) were used on a Varian Prostar HPLC system equipped with Prostar 210 pumps and a Prostar 335 photodiode array detector (PDA), with data collected and analyzed using Galaxie Chromatography Workstation software (version1.9.3.2, Varian Inc.). Flash chromatography was conducted on a Teledyne ISCO CombiFlash Rf using Silica Gold columns and monitored by UV and evaporative light-scattering detectors (both from Teledyne Isco, Lincoln, NE, USA).
+ Open protocol
+ Expand
2

Melting Point and Chromatographic Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Melting points were determined on a Thomas-Hoover capillary tube apparatus. Thin layer chromatography was carried out using Merck Silica Gel 60F254 TLC plates; visualization was under UV. High pressure liquid chromatography was carried out on a system comprised of two Rainin Dynamax Pumps Model SD-300 equipped with a Rheodyne Model 7725i Injector, and a Varian ProStar 330 Detector; the system was controlled using Varian Star Version 5.5.
Chromatographic purification was performed on a Teledyne ISCO CombiFlash Rf. Nuclear magnetic resonance (NMR) spectra were recorded on a Bruker Avance 300 MHz or a Varian Unity Inova 500 MHz NMR spectrometer. Microanalyses were performed by Atlantic Microlab, Inc. X-ray diffraction analysis was carried out by the Naval Research Laboratory.
+ Open protocol
+ Expand
3

Analytical Thin-Layer Chromatography and Flash Column Purification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analytical thin-layer chromatography was performed using Sorbent Technologies 250 μm glass-backed UV254 silica gel plates. The plates were first visualized by means of fluorescence upon 254 nm irradiation then using an iodine chamber and subsequently with phosphomolybdic acid with heating. Flash column chromatography was performed using Sorbent Technologies 40–63 μm, pore size 60 Å silica gel in Luknova columns on a Teledyne ISCO CombiFlash Rf with solvent systems indicated. Solvent removal was effected using a Buchi R3 rotary evaporator with a V900 diaphragm pump (~10 mmHg). Further drying of samples was conducted using a Welch vacuum pump at <0 mmHg. All isolated yields refer to material that is chromatographically (TLC or HPLC) and spectroscopically (1H NMR) homogenous.
+ Open protocol
+ Expand
4

Optimized Synthetic Reactions Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All synthetic reactions were
carried out in oven-dried vessels under a dry N2 atmosphere.
All chemicals were obtained from commercial sources and used as received.
THF was freshly distilled over Na/benzophenone prior to use. CDCl3 and DMF were dried using molecular sieves (3 and 4 Å,
respectively). Microwave heating was performed using sealed flasks
on a CEM Discover System 908010. Automated flash column chromatography
was performed on a Teledyne ISCO CombiFlash Rf+ Lumen automated
flash chromatography System with UV/vis detection. 1H, 13C, and 19F NMR spectra were measured at ambient
temperature using 5 mm diameter NMR tubes. The chemical shift values
(δ) are reported in ppm relative to internal Me4Si
(0 ppm for 1H and 13C NMR) or residual solvents
and internal CFCl3 (0 ppm for 19F NMR). High-resolution
MS spectra (HRMS) were recorded on an LTQ Orbitrap XL using electrospray
(ESI) or APCI ionization on a Waters Micromass AutoSpec Ultima or
Agilent 7890A GC coupled with Waters GCT Premier orthogonal acceleration
TOF detector using electron impact (EI) or chemical ionization (CI).
Simultaneous thermogravimetric and differential scan calorimetry (TG-DSC)
was carried out using a Setaram Sensys Evo thermal analyzer equipped
with a symmetrical balance and a Calvet 3D sensor.
+ Open protocol
+ Expand
5

Characterization of Synthetic Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reagents were purchased from Sigma-Aldrich, TCI, and Acros and were used without further purification unless otherwise specified. Solvents were purchased from Sigma-Aldrich and Fisher Scientific, and dried by standard techniques. NMR solvents were purchased from Cambridge Isotope Laboratories (Andover, MA). All reactions were monitored with analytical TLC (Merck Kieselgel 60 F254). Column chromatography was carried out with Teledyne ISCO Combiflash Rf with silica gel particle size 40–63 um. NMR spectra were obtained on Varian Mercury 300 MHz and Varian VX 500 MHz. Mass spectra were obtained on an Agilent 6230 HR-ESI-TOF MS at the Mass Spectrometry Facility at the UCSD Chemistry and Biochemistry Department.
+ Open protocol
+ Expand
6

Characterization of Organic Compounds via Spectroscopic Techniques

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chemical reagents purchased from commercial suppliers were not further purified prior to use. Flash column chromatography was performed using silica gel (4-63 mm) purchased from Sorbent Technologies. Other chemical separations were performed using a Teledyne Isco CombiFlash Rf. A Biotage microwave reactor was used when microwaving was necessary. 1H and 13C NMR were recorded using a 500 MHz Bruker AVIII spectrometer equipped with a cryogenically-cooled carbon observe probe. Tetramethylsilane was used as an internal standard and chemical shifts (δ) are reported in ppm and coupling constants (J) are reported in Hz. High-resolution mass spectrometry (HRMS) was performed using an electrospray ion source in either positive or negative mode on an LCT Premier (Micromass Ltd., Manchester UK). Melting points were measured with a Thomas Capillary Melting Point Apparatus and are uncorrected. Chiral analysis was carried out using HPLC, 1 ml/min hexane:isopropanol (90:10) on a CHIRALCEL® OD-H column, monitored at 320 nm unless otherwise specified.
+ Open protocol
+ Expand
7

Analytical Techniques for Compound Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were used in the condition received from commercial sources. 1H NMR and 13C NMR were taken in CDCl3 or DMSO-d6 at room temperature on Varian Inova 400 or 500 MHz instruments. Reported chemical shifts are expressed in parts per million (ppm) on the δ scale from an internal standard of tetramethylsilane (0 ppm). Mass spectrometry data were obtained on either an Agilent TOF or Agilent Q-TOF. An Agilent 1100 series HPLC with an Agilent Zorbax Eclipse Plus−C18 column was used to determine purity of biologically tested compounds. All tested compounds were determined to be >95% pure using a 6 minute gradient of 10–90% acetonitrile in water followed by a 2 minute hold at 90% acetonitrile with detection at 254 nm. Flash chromatographic purifications were performed using a Teledyne ISCO Combiflash RF with Redisep Gold RF columns.
+ Open protocol
+ Expand
8

Purification and Characterization Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were used in the condition received from commercial sources. Flash chromatographic purifications were performed using a Teledyne ISCO Combiflash RF with Redisep Gold RF silica columns. 1H NMR and 13C NMR were taken in CDCl3 or DMSO-d6 at room temperature on Varian Inova 400 or 500 MHz instruments. Reported chemical shifts are expressed in parts per million (ppm) on the δ scale from an internal standard of tetramethylsilane (0 ppm). Mass spectrometry data were obtained on either an Agilent TOF or Agilent Q-TOF. An Agilent 1100 series HPLC with an Agilent Zorbax Eclipse Plus-C18 column was used to determine purity of biologically tested compounds. All tested compounds were determined to be >95% pure using a 6 min gradient of 10-90% acetonitrile in water followed by a 2 min hold at 90% acetonitrile with detection at 254 nm. Enantiomeric excesses were determined by chiral analytical HPLC using a Daicel Chiralcel OD column 4.6X250mm. Optical rotations were determined by Robertson Microlit Laboratories (http://www.robertson-microlit.com) according to USP <781S> protocol.
NCT-506 used as a comparator in biological studies was prepared as described by Yang et al.36 (link)
+ Open protocol
+ Expand
9

Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were used without further purification as received from commercial sources unless noted otherwise. 1H NMR spectra were taken in DMSO-d6, MeOD, or CDCl3 at room temperature on Varian Inova 400 MHz or Varian Inova 500 MHz instruments. Reported chemical shifts for the 1H NMR and 13C NMR spectra were recorded in parts per million (ppm) on the δ scale from an internal standard of residual tetramethylsilane (0 ppm). Mass spectrometry data were obtained on either a Micromass LCT or Agilent Q-TOF. An Agilent 1100 series HPLC with an Agilent Zorbax Eclipse Plus–C18 column was used to determine purity of biologically tested compounds. Unless otherwise noted, all tested compounds were determined to be >95% pure using a 6 minute gradient of 10–90% acetonitrile in water followed by a 2 minute hold at 90% acetonitrile with detection at 254 nm. Flash chromatographic purifications were performed using a Teledyne ISCO Combiflash RF with Redisep Gold RF columns.
+ Open protocol
+ Expand
10

Synthesis and Purification of Venglustat

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents and solvents were used in the condition received from commercial sources. Chromatographic purifications were performed using a Teledyne ISCO Combiflash RF with Redisep columns or by standard flash chromatography using silica gel (220−240 mesh) obtained from Silicycle. 1H NMR were taken in CDCl3 or DMSO-d6 at room temperature on Varian Inova 400 or 500 MHz instruments. Reported chemical shifts are expressed in parts per million (ppm) on the δ scale from an internal standard of tetramethylsilane (0 ppm). Mass spectra were recorded on a Micromass LCT time-of-flight instrument utilizing the electrospray ionization mode. An Agilent 1100 series HPLC with an Agilent Zorbax Eclipse Plus−C18 column (3.5 um, 4.6 × 100 mm) was used to determine “HPLC purity” of biologically tested compounds. All tested compounds were assayed for purity using a 6 min gradient of 10−90% acetonitrile in water followed by a 2 min hold at 90% acetonitrile with detection at 254 nm.
Eliglustat tartrate used in these studies was obtained from Genzyme Corporation. Genz-682452 (3, venglustat) was prepared by the method described by Zhao et al.19
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!