Mobile phases for the determination of polyphenols in standard solutions and condensate water samples was 5% methanol-0.1% formic acid in water (eluent A) and 95% methanol-0.1% formic acid in water (eluent B). The gradient was as follows: 0-5 min, 100% A; 5-45 min, linear gradient up to 100% B; 45-55 min 100% B; 55-57 min, linear gradient up to 100% A. Post-run time was 15 min. Elution was performed at a solvent flow rate of 0.8 mL min-1. Table S1 summarized the retention time (tR), solvent used for stock solution preparation and spectra information (UV absorbance (λmax) and fluorescence (λexcitation/ λemission)) of 31 polyphenols standards separated using the above conditions. ChromQuest™ 4.2 Chromatography Data System was used to carry out HPLC-DAD/FD control, data acquisition and data analysis.
C18 spherisorb s5 ods2
The C18 Spherisorb S5 ODS2 is a reversed-phase high-performance liquid chromatography (HPLC) column. It features silica-based packing material with chemically bonded octadecyl (C18) functional groups. This column is designed for the separation and analysis of a wide range of compounds, including polar and non-polar molecules.
3 protocols using c18 spherisorb s5 ods2
HPLC-DAD-FD Analysis of Polyphenols
Mobile phases for the determination of polyphenols in standard solutions and condensate water samples was 5% methanol-0.1% formic acid in water (eluent A) and 95% methanol-0.1% formic acid in water (eluent B). The gradient was as follows: 0-5 min, 100% A; 5-45 min, linear gradient up to 100% B; 45-55 min 100% B; 55-57 min, linear gradient up to 100% A. Post-run time was 15 min. Elution was performed at a solvent flow rate of 0.8 mL min-1. Table S1 summarized the retention time (tR), solvent used for stock solution preparation and spectra information (UV absorbance (λmax) and fluorescence (λexcitation/ λemission)) of 31 polyphenols standards separated using the above conditions. ChromQuest™ 4.2 Chromatography Data System was used to carry out HPLC-DAD/FD control, data acquisition and data analysis.
HPLC Quantification of Antioxidant Compounds
HPLC-DAD-FD Analysis of Polyphenols
Mobile phases for the determination of polyphenols in standard solutions and condensate water samples was 5% methanol-0.1% formic acid in water (eluent A) and 95% methanol-0.1% formic acid in water (eluent B). The gradient was as follows: 0-5 min, 100% A; 5-45 min, linear gradient up to 100% B; 45-55 min 100% B; 55-57 min, linear gradient up to 100% A. Post-run time was 15 min. Elution was performed at a solvent flow rate of 0.8 mL min-1. Table S1 summarized the retention time (tR), solvent used for stock solution preparation and spectra information (UV absorbance (λmax) and fluorescence (λexcitation/ λemission)) of 31 polyphenols standards separated using the above conditions. ChromQuest™ 4.2 Chromatography Data System was used to carry out HPLC-DAD/FD control, data acquisition and data analysis.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!