Quantitative Analysis of Paraquat and Diquat

Check if the same lab product or an alternative is used in the 5 most similar protocols
Paraquat (99.2%, batch number 6320x) and diquat (99.8%, batch number 20 160 323) were purchased from Sigma‐Aldrich Labor Chemikalien GMBH (Milwaukee, USA) and Shanghai Pesticide Research Institute Co., Ltd., respectively (Shanghai, China). Acetonitrile (chromatographic pure, batch number 0 000 152 366) and methanol (chromatographic pure, batch number 0 000 189 995) were provided by JT Baker (Phillipsburg, USA). Sodium heptane sulfonate (batch number 20171012s1210) was provided by Agela Technologies (Tianjin, China). Ethyl acetate (chromatography pure, batch number 151 331 612) was provided by AppliChem (Darmstadt, Germany). Phosphoric acid (85%, chromatography pure) was provided by Fisher Scientific‐Janssen Physicalaan (Geel, Belgium). Ammonium formate (chemical pure, batch number 990 215) and potassium dihydrogen phosphate (>99.5%, analytical pure) were provided by China Pharmaceutical (Group) Shanghai Chemical Reagent Co., Ltd. (Shanghai, China) and Shandong Chemical Research Institute (Jinan, China), respectively. Purified water was provided by Hangzhou Wahaha Group Co., Ltd. (Hangzhou, China). Blank human plasma was obtained from healthy donors collected and stored immediately at −20°C until analysis, which was approved by the ethics committee of Qilu Hospital of Shandong University. The signed informed consent was obtained from each donor.
+ Open protocol
+ Expand
2

Quantification of antihypertensive drugs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reference substances of lercanidipine, telmisartan and valsartan were obtained from Sigma-Aldrich GmbH (Steinheim, Germany). Amlodipine and candesartan, as well as the deuterated internal standards (IS) diazepam-d5, lorazepam-d4 and nordiazepam-d5 were purchased from LGC Standards GmbH (Wesel, Germany).
Acetonitrile was obtained from Karl Roth GmbH (Karlsruhe, Germany) and ethyl acetate from AppliChem (Darmstadt, Germany). Further chemicals and solvents used were supplied by Sigma-Aldrich GmbH (Steinheim, Germany). All reagents and solvents were either of analytical or LC grade.
+ Open protocol
+ Expand
3

Quantitative Analysis of Pharmaceutical Drugs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reference substances furosemide, torasemide, atenolol, bisoprolol and metoprolol were obtained from Sigma-Aldrich GmbH (Steinheim, Germany). Hydrochlorothiazide (HCT), canrenone and nebivolol, as well as the deuterated internal standards (IS) ketamine-d4, haloperidol-d4, diazepam-d5, quetiapine-d8, oxazepam-d5 and methadone-d9 were purchased from LGC Standards GmbH (Wesel, Germany). HCT-d2 was obtained from Toronto Research Chemicals (North York, Canada).
Acetonitrile was obtained from Karl Roth GmbH (Karlsruhe, Germany) and ethyl acetate from AppliChem (Darmstadt, Germany). Further chemicals and solvents used were supplied by Sigma-Aldrich GmbH (Steinheim, Germany). All reagents and solvents were either of analytical or LC grade.
+ Open protocol
+ Expand
4

Quantitative Analysis of 4-FA

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reference substance of 4-FA and the deuterated internal standard 4-FA-d 5 (ISTD) were purchased from LGC Standards (Wesel, Germany). UPLC-grade water and UPLC-grade acetonitrile were purchased from VWR Chemicals (Darmstadt, Germany), ethyl acetate was from AppliChem (Darmstadt, Germany), and methanol was from Sigma-Aldrich (Steinheim, Germany). All other reagents and solvents were purchased from Merck (Darmstadt, Germany) and were of analytical or HPLC grade.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!