The largest database of trusted experimental protocols

Chelex 100 resin 50 100 mesh

Manufactured by Merck Group
Sourced in United States

Chelex 100 resin (50-100 mesh) is a chelating ion exchange resin composed of a styrene-divinylbenzene copolymer matrix with paired iminodiacetate functional groups. It is used for the selective removal of metal ions from aqueous solutions.

Automatically generated - may contain errors

7 protocols using chelex 100 resin 50 100 mesh

1

Synthesis and Characterization of Functionalized Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
TRC105 was provided by TRACON Pharmaceuticals Inc. (San Diego, CA). p-SCN-Bn-NOTA (i.e., 2-S-(4-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid) was acquired from Macrocyclics, Inc. (Dallas, TX). NHS-fluorescein, hematoxylin staining solution, and Chelex 100 resin (50–100 mesh), tetraethyl orthosilicate (TEOS), triethanolamine (TEA), (3-Aminopropyl)triethoxysilane (APS), Cetyltrimethylammonium chloride solution (CTAC, 25 wt %), copper(II) chloride (CuCl2), sodium sulfide nonahydrate (Na2S·9H2O) and dodium citrate dehydrate were purchased from Sigma-Aldrich (St. Louis, MO). AlexaFluor488- and Cy3-labeled secondary antibodies were purchased from Jackson Immunoresearch Laboratories, Inc. (West Grove, CA). PD-10 columns were purchased from GE Healthcare (Piscataway, NJ). Absolute ethanol, sodium chloride (NaCl), doxorubicin hydrochloride (DOX) were purchased from Fisher Scientific. SCM-PEG5k-Mal was obtained from Creative PEGworks. Water and all buffers were of Millipore grade and pretreated with Chelex 100 resin to ensure that the aqueous solution was free of heavy metals. All chemicals were used as received without further purification.
+ Open protocol
+ Expand
2

Radiolabeling of NOTA-Prdx1 Conjugate

Check if the same lab product or an alternative is used in the 5 most similar protocols
The details of the reagents and cell culture are provided in the Supplemental Materials. S-2-(4-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid (p-SCN-Bn-NOTA) was purchased from Macrocyclics, Inc. (Plano, TX, USA). Chelex 100 resin (50–100 mesh) was purchased from Sigma-Aldrich (St. Louis, MI, USA). PD-10 desalting columns were purchased from GE Healthcare (Chicago, IL, USA). Prdx1 was acquired from Sinobiological (Beijing, China). All other reaction buffers and chemicals were purchased from Thermo Fisher Scientific (Fisher store in Stanford, USA).
+ Open protocol
+ Expand
3

Synthesis and Characterization of cRGDyK Peptide Conjugates

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cyclo-(Arg-Gly-Asp-D-Tyr-Lys) peptide (cRGDyK) was procured from Peptide International (Louisville, KY). PD-10 columns were purchased from GE Healthcare (Piscataway, NJ). Absolute ethanol, cyclohexane and sodium chloride (NaCl) were purchased from Fisher Scientific (Pittsburg, PA). Sunitinib was purchased from LC Laboratories (Woburn, MA). SCM-PEG5k-Mal was obtained from Creative PEG works (Winston Salem, NC). p-SCN-Bn-NOTA was acquired from Macrocyclics, Inc.(Dallas, TX). NHS-Fluorescein, Chelex 100 resin (50–100 mesh), tetraethyl orthosilicate(TEOS), ammonia (NH3.H2O), Igepal CO-520 (NP-5), triethylamine (TEA), (3-Aminopropyl)triethoxysilane (APS), dimethyl sulfoxide (DMSO), cetyltrimethylammonium chloride (CTAC, 25 wt%) and Kaiser test kit were purchased from Sigma-Aldrich (St. Louis, MO). Traut’s Reagent (2-Iminothiolane. HCl) and PBS (1X) were purchased from Thermo Scientific (Rockford, IL). Water and all buffers were of Millipore grade and pretreated with Chelex 100 resin to ensure that the aqueous solution was free of heavy metals. All chemicals were used as received without further purification.
+ Open protocol
+ Expand
4

Radiolabeling and Imaging of CD31

Check if the same lab product or an alternative is used in the 5 most similar protocols
ALT-836 was provided by Altor Bioscience Corporation (Miramar, FL). S-2-(4-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid (p-SCN-Bn-NOTA) was purchased from Macrocyclics, Inc. (Dallas, TX). Chelex 100 resin (50-100 mesh) and fluorescein isothiocyanate (FITC) were acquired from Sigma-Aldrich (St. Louis, MO). Rat anti-mouse CD31 primary antibody was purchased from BD Biosciences (San Diego, CA). AlexaFluor488- and Cy3-labeled secondary antibodies were purchased from Jackson Immunoresearch Laboratories, Inc. (West Grove, CA). PD-10 desalting columns were purchased from GE Healthcare (Piscataway, NJ). 64Cu was produced by a GE PETrace cyclotron using the 64Ni(p,n)64Cu reaction, which has specific activity of > 5 Ci/μmol at the end of bombardment. Water and all buffers were of Millipore grade and pretreated with Chelex 100 resin to ensure that the aqueous solution was free of heavy metals. All other reaction buffers and chemicals were from Thermo Fisher Scientific.
+ Open protocol
+ Expand
5

Highly Pure Radiolabeling Procedure

Check if the same lab product or an alternative is used in the 5 most similar protocols
All purchased chemicals were of the highest purity available and used without further purification. Metallic natural Ca (99.999%) and Chelex 100 resin (50-100 mesh) were obtained from Sigma Aldrich (St. Louis, MO). (cRGD)2 was obtained from Peptide International Inc. (Louisville, KY) and 2-(p-isothiocyanatobenzyl)-1,4,7,10-tetraazacyclododecane-N,N′,N′′,N′′′-tetraacetic acid (p-SCN-Bn-DOTA) was purchased from Macrocyclics (Dallas, TX). Diamyl, amylphosphonate extraction resin (UTEVA) was acquired from Eichrom Technologies LLC (Lisle, IL). The rest of materials and reagents were obtained from Thermo Fisher Scientific (Fair Law, NJ). Water and all buffers were of milliQ grade (resistivity >18.2MΩ·cm) and were treated with Chelex 100 resin to remove heavy metal contaminants.
+ Open protocol
+ Expand
6

VEGF121 Conjugation and Labeling

Check if the same lab product or an alternative is used in the 5 most similar protocols
VEGF121 was provided by GenScript Corp. (Piscataway, NJ). S-2-(4-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid (p-SCN-Bn-NOTA) was purchased from Macrocyclics, Inc. (Dallas, TX). Chelex 100 resin (50-100 mesh) and fluoresce in isothiocyanate (FITC) were purchased from Sigma-Aldrich (St. Louis, MO). Succinimidyl carboxymethyl PEG maleimide (SCM-PEG-Mal; molecular weight: 5 kDa; Creative PEGworks, Winston Salem, NC), rat anti-mouse CD31 primary antibody (BD Biosciences, San Diego, CA), AlexaFluor488- or Cy3-labeled secondary antibodies (Jackson Immunoresearch Laboratories, Inc., West Grove, CA), Bevacizumab (Avastin, Genentech, San Francisco, CA) and PD-10 desalting columns (GE Healthcare, Piscataway, NJ) were all acquired from commercial sources. Water and all buffers were of Millipore grade and pre-treated with Chelex 100 resin to ensure that the aqueous solution was free of heavy metal. All other reaction buffers and chemicals were obtained from Thermo Fisher Scientific (Fair Lawn, NJ).
+ Open protocol
+ Expand
7

Bioconjugation of TRC105 with NOTA

Check if the same lab product or an alternative is used in the 5 most similar protocols
TRC105 was provided by TRACON Pharmaceuticals Inc. (San Diego, CA). p-SCN-Bn-NOTA (i.e., 2-S-(4-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7- triacetic acid) was acquired from Macrocyclics, Inc. (Dallas, TX). NHS-fluorescein, hematoxylin staining solution, and Chelex 100 resin (50~100 mesh), tetraethyl orthosilicate (TEOS), triethanolamine (TEA), (3-Aminopropyl)triethoxysilane (APS), Cetyltrimethylammonium chloride solution (CTAC, 25 wt%), copper(II) chloride (CuCl2), sodium sulfide nonahydrate (Na2S·9H2O) and dodium citrate dehydrate were purchased from Sigma-Aldrich (St. Louis, MO). AlexaFluor488- and Cy3-labeled secondary antibodies were purchased from Jackson Immunoresearch Laboratories, Inc. (West Grove, CA). PD-10 columns were purchased from GE Healthcare (Piscataway, NJ). Absolute ethanol, sodium chloride (NaCl), doxorubicin hydrochloride (DOX) were purchased from Fisher Scientific. SCM-PEG5k-Mal was obtained from Creative PEGworks. Water and all buffers were of Millipore grade and pretreated with Chelex 100 resin to ensure that the aqueous solution was free of heavy metals. All chemicals were used as received without further purification.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!