Acquity 1 class plus ultra high performance liquid chromatography

Manufactured by Waters Corporation

The Acquity I-Class PLUS is an ultra-high performance liquid chromatography system manufactured by Waters Corporation. It is designed to provide high-resolution separation and accurate quantification of complex samples.

Automatically generated - may contain errors

2 protocols using acquity 1 class plus ultra high performance liquid chromatography

1

LC-MS Metabolomics Protocol with QTOF

Check if the same lab product or an alternative is used in the 5 most similar protocols
The LC/MS system used for metabolomics analysis consists of the Waters Acquity I-Class PLUS ultra-high performance liquid chromatography coupled with the Waters Xevo G2-XS QTof high-resolution mass spectrometer. The column used was purchased from Waters and is the Acquity UPLC HSS T3 column (1.8 μm, 2.1 × 100 mm). The Waters Xevo G2-XS QTof high-resolution mass spectrometer can collect primary and secondary mass spectrometry data in MSe mode under the control of the acquisition software (MassLynx V4.2, Waters, Shanghai, China). During each data acquisition cycle, simultaneous dual-channel data acquisition can be performed at low and high collision energy. The raw data collected using MassLynx V4.2 (MassLynx V4.2, Waters, Shanghai, China) was subjected to data processing operations such as peak extraction and peak alignment using Progenesis QI (Progenesis QI, Waters, Shanghai, China) software. Identification was performed using the online METLIN database and a custom-built library in Progenesis QI (Progenesis QI, Waters, Shanghai, China) software. The identification process involved theoretical fragment identification and a mass deviation within 100 ppm.
+ Open protocol
+ Expand
2

Metabolomic Analysis of Stool and Urine

Check if the same lab product or an alternative is used in the 5 most similar protocols
A total of 50 mg of stool and 100 µL of urine samples were weighed and extracted with 1000 and 500 µL of 2-chlorophenylalanine in formaldehyde configuration, respectively. A liquid chromatography–mass spectrometry system was used for metabolomics analysis (Waters Acquity I-Class PLUS ultrahigh performance liquid chromatography in series with Waters Xevo G2-XS QTof high-resolution mass spectrometer). Progenesis QI software was applied to extract and align peaks from raw data collected by MassLynx V4.2. Data quality assessment and annotation, differential expression and functional enrichment analyses were performed on the basis of the test results.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!