The largest database of trusted experimental protocols

Vitek 2

Manufactured by Thermo Fisher Scientific
Sourced in United Kingdom

The VITEK 2 is an automated microbiology system used for the identification and susceptibility testing of microorganisms. It provides rapid and accurate results for clinical diagnostic laboratories.

Automatically generated - may contain errors

4 protocols using vitek 2

1

Bacterial Identification and Antibiotic Susceptibility

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood was cultured using a BacT/ALERT 3D system (Becton-Dickinson, Sparks, MD, USA) in the microbiology laboratory. Species identification was performed using Bruker Daltonics DataAnalysis. Antibiotic susceptibility testing was performed using the VITEK 2 (Card number: AST-GN16; AST-GP67) system or the Kirby–Bauer Disk Diffusion method (Oxoid, UK) according to the recommendations proposed by the Clinical and Laboratory Standards Institute (CLSI).
+ Open protocol
+ Expand
2

Blood Culture and Antimicrobial Susceptibility

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood culture by using the BacT/ALERT 3D system (Becton–Dickinson, Sparks, MD, USA), species identification, and antibiotic susceptibility were carried out by using the VITEK-2 (Card number: AST-GN334; AST-GP67) compact automatic microbiological analyzer (Oxoid, UK) according to the recommendations proposed by the Clinical and Laboratory Standards Institute (CLSI).
+ Open protocol
+ Expand
3

Bacterial Identification and Antibiotic Susceptibility

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood was cultured using a BacT/ALERT 3D system (Becton-Dickinson, Sparks, MD, USA) in the microbiology laboratory. Species identification was performed using Bruker Daltonics DataAnalysis. Antibiotic susceptibility testing was performed using the VITEK 2 (Card number: AST-GN16; AST-GP67) system or the Kirby-Bauer Disk Diffusion method (Oxoid, UK) according to the recommendations proposed by the Clinical and Laboratory Standards Institute (CLSI).
+ Open protocol
+ Expand
4

Automated Blood Culture and Antimicrobial Susceptibility

Check if the same lab product or an alternative is used in the 5 most similar protocols
An automated BacT/ALERT 3D system (Becton-Dickinson, Sparks, MD) was used to culture blood. Species identification was performed using Bruker Daltonics Data Analysis. As recommended by Clinical & Laboratory Standards Institute, antibiotic susceptibility testing was performed using the VITEK 2 (Card number: AST-GN16; AST-GP67) system or the Kirby-Bauer disk diffusion method (Oxoid, Hampshire, UK).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!