Biacore amine coupling kit

Manufactured by Cytiva

The Biacore Amine Coupling Kit is a laboratory equipment product designed for the immobilization of proteins and other biomolecules onto sensor surfaces. The kit provides the necessary reagents and buffers to facilitate the covalent coupling of amine-containing molecules to the sensor chip surface.

Automatically generated - may contain errors

2 protocols using biacore amine coupling kit

1

Biacore T200 Binding Kinetics

Check if the same lab product or an alternative is used in the 5 most similar protocols
A Biacore T200 spectrometer Cytiva (Uppsala, Sweden) instrument was used. 3C-like proteinase (Mybiosource), Biacore Amine Coupling Kit (Cytiva), Series S Sensor Chip CM5 (Cytiva), and phosphate-buffered saline (PBS) containing 9.2% DMSO at pH 7.4 was used as running buffer.
+ Open protocol
+ Expand
2

SPR Analysis of Antibody-Complement C7 Binding

Check if the same lab product or an alternative is used in the 5 most similar protocols
Surface plasmon resonance experiments were performed on a Biacore 8K instrument (Cytiva) using HBS-EP+ (Teknova) at pH 7.4 as a running buffer. For the SPR chip, Protein A (Pierce) was immobilized on a CM5 chip (Cytiva) using a Biacore amine coupling kit (Cytiva) according to the manufacturer’s instructions. Multi-cycle kinetics experiments were run as follows. Antibodies were diluted in running buffer to 0.5μg/ml and captured on the sample flow cells of all channels at a flow rate of 10 μL/min for 60s. Antigen was flowed over both flow cells of all channels at a flow rate of 30μl/min for 180s followed by a 600s dissociation time. The chip surface was regenerated between cycles using 50mM NaOH for 30s at a flow rate of 30μL/min. Antigen concentrations used were 0, 0.39, 1.56, 6.25 and 25nM. The data was analyzed in the Biacore analysis software to a 1:1 binding model using local Rmax and double referencing. Off-rates fitted as slower than 1x10-5 1/s and too slow to be fitted reliably were manually adjusted to 1x10-5 1/s. Antigens used were human complement C7 (Complement Tech) and cyno complement C7 purified from cynomolgus serum (Seralab).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!

  Request a quote for « Biacore amine coupling kit »