The largest database of trusted experimental protocols

Particle agglutination kit

Manufactured by Fujirebio
Sourced in Japan

The Particle Agglutination Kit is a laboratory equipment used for the detection and analysis of agglutination reactions. It facilitates the evaluation of the presence and characteristics of specific particles or analytes in a sample through the observation of their aggregation or clumping behavior.

Automatically generated - may contain errors

2 protocols using particle agglutination kit

1

Thyroid Function Biomarkers: Measurement and Reference Ranges

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum concentrations of free T4 (FT4), free T3 (FT3), and thyrotropin (TSH) were measured using ECLIA kit (Roche Diagnostics Ltd., Tokyo, Japan). Normal ranges of serum FT4, FT3, and TSH are 0.9-1.7 ng/dL, 2.3-4.3 pg/mL, and 0.5-5.0 μIU/mL, respectively. TgAb and McAb were measured using a particle agglutination kit (Fujirebio Inc., Tokyo, Japan). A reciprocal titer >1:100 was considered positive. Serum TRAb at onset was measured by radioreceptor assay using a commercial kit (Cosmic Corp., Tokyo, Japan) as part of routine studies. Serum TRAb at the time of sampling was determined by ECLIA kit (third-generation) (Roche Diagnostics Ltd., Tokyo, Japan) using preserved samples. Normal value of TRAb was less than 10% in the radioreceptor assay and 2.0 IU/L in ECLIA. Goiter size in this study was defined as the longitudinal length of the thyroid gland as measured using a vernier caliper.
+ Open protocol
+ Expand
2

Thyroid Hormone Measurement and Autoantibody Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
The serum concentration of free T4 (FT4), free T3 (FT3) and thyrotropin (TSH) were measured using ECLIA (Roche diagnostics Ltd., Tokyo, Japan). The normal range of serum FT4, FT3 and TSH are 0.9-1.7 ng/dL, 2.3-4.3 pg/mL and 0.6-5.0 μIU/mL, respectively. TgAb and McAb were measured using a particle agglutination kit (Fujirebio Inc., Tokyo, Japan). A reciprocal titer of >1:100 was considered positive. Serum TRAb at the onset was measured by a radioreceptor assay using a commercial kit (Cosmic Corporation, Tokyo, Japan) as a part of routine studies. Serum TRAb at sampling was determined using ECLIA (third-generation) (Roche diagnostics Ltd., Tokyo, Japan) with preserved samples. The normal value of TRAb is less than 10% and 2.0 IU/L.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!