The largest database of trusted experimental protocols

5 protocols using unityinova 500 nmr spectrometer

1

Synthesis of Poly(γ-GA-co-γ-DSGA) Conjugate

Check if the same lab product or an alternative is used in the 5 most similar protocols
The synthetic route of poly(γ-GA-co-γ-DSGA) is illustrated in Figure 1a. To partially activate the γ-GA residues of poly(γ-GA) into the reactive γ-GAOSu moieties, NHS (50 mol % with respect to the γ-GA residues) and DCC (equal to molar concentration of NHS) used as the coupling agent were added to the solution of poly(γ-GA) in DMSO/pyridine (3/1 (v/v)). The reaction was carried out at 4°C for 48 h. The undesired product, N,N’-dicyclohexylurea (DCU), was then removed by the repeated filtration of the concentrated polymer solution. The partial transesterification of poly(γ-GA-co-γ-GAOSu) with distearin (25 mol% with respect to the original γ-GA residues in poly(γ-GA)) was then conducted at 60°C for 7 days, using 4-dimethylaminopyridine as the catalyst. This was followed by the dialysis (Cellu Sep MWCO 12000∼14000) against DMSO/THF (3/1 (v/v) solution) to eliminate the unreacted lipid species. Afterward, full hydrolysis of the remaining γ-GAOSu into the γ-GA residues was achieved by the addition of pH 7.4 tris buffer. The solution was then dialyzed (Cellu Sep MWCO 12000∼14000) against deionized water to remove NHS, DMSO and THF. Finally, the purified lipid/polypeptide conjugate was collected by lyophilization. The chemical composition was determined by 1H-NMR (Varian Unityinova 500 NMR Spectrometer) using DMSO-d6 as the solvent.
+ Open protocol
+ Expand
2

Quantifying GelMA Substitution Degree

Check if the same lab product or an alternative is used in the 5 most similar protocols
A TNBS (2,4,6-trinitrobenzene sulfonic acid, ThermoFisher) assay was performed to quantify the degree of GelMA substitution, according to the manufacturer’s instructions. Briefly, GelMA and gelatin samples were separately dissolved at 1.6 mg/mL in 0.5 mL of 0.1 m sodium bicarbonate buffer. Then, each sample was mixed with 0.5 mL of 0.01% TNBS solution in 0.1 m sodium bicarbonate buffer and incubated at 37°C for 2 h. Next, 0.25 mL of 1 m hydrochloric acid and 0.5 mL of 10 wt% sodium dodecyl sulfate (SDS) were added to stop the reaction. The absorbance of each sample was measured at 335 nm, and the extent of substitution was calculated by comparing the amount of remaining free amine groups in GelMA to that of an unmodified gelatin control. 1H NMR measurement was also performed to verify the degree of substitution. Briefly, GelMA and gelatin samples were separately dissolved at approximately 50 mg/mL in deuterium oxide, and the NMR spectra were recorded on a Varian Unity INOVA 500 NMR spectrometer (1H NMR, 499.75 MHz).
+ Open protocol
+ Expand
3

Synthesis and Characterization of Epoxidized Soybean Oil Copolymers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Epoxidized Soybean Oil (ESO) was obtained from Sankim (İstanbul, Turkey), maleic anhydride (MA), 2-chloroethanol (CE), 4-(dimethylamino)pyridine (DMAP), zinc chloride, hydroquinone, styrene (ST), sodium iodide, tetrahydrofuran (THF), triethylamine (TEA) were purchased from Merck (Darmstadt, Germany). All of these chemicals were used without any further purification. FTIR spectra of the compounds and copolymers were performed by Bruker Optics Vertex 70 spectrometer using ATR (attenuated total reflection) techniques from 4000 cm−1 to 400 cm−1. 1H NMR spectra were acquired by a Varian Unity Inova 500 NMR spectrometer in CDCl3. Thermal stabilities of the material were found by Shimadzu DTG 60 model TGA instrument with a 10 °C/min heating rate under nitrogen atmosphere. Differential scanning calorimetric (DSC) analyses of the copolymers were performed with a heat-flux type DSC instrument (SII Nanotechnology, ExStar 6200).
+ Open protocol
+ Expand
4

Analysis of Natural Product Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were acquired on a Jasco P-1020 polarimeter. IR spectra were obtained on a Bruker IFS-66/S FT-IR spectrometer. ESI and HR-ESI mass spectra were measured on a SI-2/LCQ DecaXP Liquid chromatography (LC)-mass spectrometer. NMR spectra, including 1H-1H COSY, HMQC, HMBC, and NOESY experiments, were recorded on a Varian UNITY INOVA 500 NMR spectrometer operating at 500 MHz (1H) and 125 MHz (13C). Chemical shifts are given in ppm (δ). Preparative high-performance liquid chromatography (HPLC) was performed using a Gilson 306 pump with a Shodex refractive index detector. silica gel 60 (Merck, Darmstadt, Germany, 230–400 mesh) and RP-C18 silica gel (Merck, 230–400 mesh) were used for column chromatography. Merck precoated silica gel F254 plates and RP-18 F254s plates were used for thin layer chromatography (TLC). Spots were detected on TLC under UV light or by heating after the spots were sprayed with anisaldehyde-sulfuric acid.
+ Open protocol
+ Expand
5

Analytical Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mass spectra were recorded on a UPLC mass spectrophotometer (Waters 2996-2695, ESI-MS). NMR spectra were recorded on a Bruker Avance DPX-300 FT-NMR spectrometer or a Varian Unity INOVA-500 NMR spectrometer. Optical rotation was measured on a Perkin-Elmer 341 polarimeter. Vacuum-liquid column chromatography (VLC) and column chromatography (CC) were performed on silica gel 60 (Merck, Kieselgel 60, 70–320 mesh), silica gel 60 (Merck, Kieselgel 60, 230–400 mesh), and Sephadex LH-20 (25–100 μm, Pharmacia Fine Chemical Co. Ltd.).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!