Sc-74540 is a laboratory instrument used for the detection and analysis of biological samples. It is designed to perform various analytical functions, including spectroscopy, chromatography, and imaging. The core function of this product is to provide accurate and reliable data to support scientific research and discovery.

Automatically generated - may contain errors

2 protocols using sc 74540

1

Immunohistochemical Analysis of Osteoclasts

Check if the same lab product or an alternative is used in the 5 most similar protocols
After euthanasia, mouse femurs were isolated and fixed in 4% paraformaldehyde (PFA) at 4 °C overnight. Next, specimens were decalcified in 10% EDTA, dehydrated, embedded in paraffin, and sectioned into 4.5 μm thick slices. Sections were permeabilized in PBS containing 1% Triton X-100, blocked in normal goat serum for 30 min at 37 °C and incubated with primary antibodies against MVP (1:100, sc-18701, Santa Cruz, Texas, America), CTSK (1:100, sc-48353, Santa Cruz) and Cleaved-Caspases3 (1:100, #9664, Cell Signaling Technology, Massachusetts, America) 4 °C overnight. On the second day, sections were incubated with secondary antibodies for 1 h at 37 °C and finally stained with 4’,6-diamidino-2- phenylindole (DAPI) (Beyotime, Shanghai, China) for 2 min at room temperature.
For in vitro studies, osteoclasts were harvested in 4% PFA for 15 min at room temperature, permeabilized with 0.5% Triton X-100 and blocked with normal goat serum at 37 °C for 1 h. Then, cells were co-stained with primary antibodies against MVP (1:100, sc-18701, Santa Cruz) and Fas (1:100, sc-74540, Santa Cruz) at 4 °C overnight. The next day, after washing with PBST, cells were incubated with secondary antibodies at 37 °C for 1 h. Nuclei were stained with DAPI. Images were captured using a fluorescence microscope (Leica Microsystems, Wetzlar, Germany).
+ Open protocol
+ Expand
2

Immunoprecipitation and Ubiquitination Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cells were lysed in IP lysis buffer (P10013, Beyotime) containing protease inhibitor cocktail tablets for 15 min at 4 °C. After the protein concentrations were measured, equal levels of lysates were used for immunoprecipitation. Cell lysates were incubated with antibodies against MVP (sc-23916, Santa Cruz) or Fas (sc-74540, Santa Cruz) and protein A/G beads (sc-2003, Santa Cruz) overnight at 4 °C. Then, the precipitants were washed three times with IP lysis buffer, and the immune complexes were eluted with 2x loading buffer for 5 min at 95 °C, and subjected to western blot analysis. For ubiquitination assay, 4 h before cell harvest, 10 µΜ MG-132 (MCE, New Jersey, USA) was added into the medium.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!