Synthesis and Characterization of Polymer-TiO2 Nanocomposites

Check if the same lab product or an alternative is used in the 5 most similar protocols
Poly(N-hydroxyethyl acrylamide) (pHEAAm) was synthesized by thermally initiated radical polymerization (see Supplementary Materials). Poly(acrylic acid) (pAA, Mw = 5000) and poly(vinyl pyrrolidone) (pVP, Mw = 36,000) were purchased from FUJIFILM Wako Pure Chemical Corporation (Osaka, Japan) and Honeywell Fluka (Morristown, NJ, USA), respectively, and poly(ethylene glycol) (pEG, Mw = 20,000) and poly(vinyl alcohol) (pVA, Mw = 500) were purchased from Nacalai Tesque (Kyoto, Japan). In this study, three different aqueous dispersions of titanium oxide nanoparticles (TiNP-x) were used for fabricating polymer composites. TiNP-1 (40 nm, 0.85 wt%, PTA) and TiNP-2 (20 nm, 0.85 wt%, TPX-HP) were purchased from Kon Corporation (Saga, Japan), and TiNP-3 (70 nm, 18.1 wt%, TisolA) was kindly provided by NYACOL Nano Technologies Inc. (Ashland, MA, USA). Deionized water was prepared with an Elix UV 3 (Merck KGaA, Darmstadt, Germany) and used as a solvent.
+ Open protocol
+ Expand
2

Polymer-Supplemented Cell Culture Media

Check if the same lab product or an alternative is used in the 5 most similar protocols
High-molecular-weight (M.W.) soluble polymers and their final concentration in culture
medium (CiCM) were as follows: Poly-ethylene glycol (PEG) [M.W. 15000-25000, nacalai
tesque]: CiCM 0.5-1 mg/ml; polyvinyl alcohol (PVA) [M.W. 146000-186000, Sigma-Aldrich]:
CiCM 0.5-1 mg/ml; polyvinylpyrrolidone (PVP) [M.W. 360000, Sigma-Aldrich]: CiCM 1 mg/ml;
dextran (Dex) [M.W. 190000-230000, nacalai tesque]: CiCM 1 mg/ml; poly-γ-glutamic acid
(PGA) [M.W. 200000-500000, Wako Pure Chemical industry]: CiCM 1 mg/ml; chondroitin sulfate
C sodium salt (CSC) [M.W. 40000-80000,Wako Pure Chemical industry]: CiCM 0.5 mg/ml;
hyaluronic acid sodium salt (HRL) [M.W. not determined, Wako Pure Chemical industry]: CiCM
0.5 mg/ml; chondroitin sulfate A sodium salt (CSA) [M.W. 40000-80000, Sigma-Aldrich]: CiCM
0.5 mg/ml; dermatan sulfate sodium salt (DS) [M.W. 85000~100000, Tokyo Chemical Industry]:
CiCM 0.5 mg/ml; poly-L-lysine hydrobromide (PLL) [M.W. 30000-70000, Sigma-Aldrich] CiCM
5-50 μg/ml; poly-L-ornithine hydrobromide (PLO) [M.W. 30000-70000, Sigma-Aldrich]: CiCM
12.5 μg/ml; poly-D-lysine hydrobromide (PDL) [M.W. 30000-70000, Sigma-Aldrich]: CiCM 12.5
μg/ml; poly-L-histidine (PLH) [M.W. 5000-25000, Sigma-Aldrich]: CiCM 12.5 μg/ml.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!