The largest database of trusted experimental protocols

Ab100778

Manufactured by Abcam
Sourced in United States

Ab100778 is a laboratory equipment product offered by Abcam. It serves as a core function, but no further details can be provided in a concise, unbiased, and factual manner.

Automatically generated - may contain errors

3 protocols using ab100778

1

Oxidative Stress and Inflammatory Markers Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
DRG were dissociated with a mortar and pestle in tissue extraction reagent supplied with protease and phosphatase inhibitors as previously described.27 (link),28 (link) Assay kits for glutathione (703002, Cayman Chemical, Ann Arbor, MI, USA) (detection range: 0.25–16 μM) superoxide dismutase (706002, Cayman Chemical) (detection range: 0.005–0.050 U/ml), DNA/RNA oxidative damage (589320, Cayman Chemical) (detection range: 10.3–3,000 pg/ml), IL-1β (RLB00, R&D Systems, Minneapolis, MN) (detection range: 5–2,000 pg/ml), TNF (RTA00, R&D Systems) (detection range: 5–800 pg/ml), and CCL2 (ab100778, Abcam) (detection range: 24.67–18,000 μM), were used according to manufacturer instructions. Results were normalized to total protein levels (Bradford protein assay).
+ Open protocol
+ Expand
2

Inflammatory Cytokine Analysis in Atrial Tissue

Check if the same lab product or an alternative is used in the 5 most similar protocols
Atrial tissue was minced and homogenized using a tissue homogenizer (TissueRuptor, QIAGEN) according to the manufacturer protocol. Inflammatory cytokines and chemokines were measured using a multiplex Luminex-based assay (LXSARM, R&D Systems). Each sample was run in duplicate in a 96-well plate. IL-1β, IL-2, IL-18, and TNF-α were measured using a MAGPIX system (C4447b, Luminex). Acquired mean fluorescence data were analyzed and calculated by xPONENT software. IL-6 (ERA32RB, Invitrogen), TGF-β1 (ab119558, Abcam), PDGF-AB (ab213906, Abcam), and MCP-1 (ab100778, Abcam) were quantified using commercially available ELISAs according to the manufacturers’ protocols.
+ Open protocol
+ Expand
3

Atrial Inflammation Biomarkers Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Homogenized atrial tissue obtained after the invasive electrophysiological study was analyzed for markers of atrial inflammation using ELISAs and a custom multiplex Luminex-based assay (LXSARM, R&D Systems). Interleukin 6 (IL-6, ERA32RB, Life Sciences), IL-17 (MBS2022678, MyBioSource), platelet-derived growth factor AB (PDGF-AB, ab213906, Abcam), monocyte chemoattractant protein-1 (MCP-1, ab100778, Abcam) and transforming growth factor beta 1 (TGFβ1; ab119558, Abcam) were analyzed using commercially available ELISAs. Four analytes (IL-1β, IL-10, IL-18, tumor necrosis factor alpha (TNFα)) were measured using a MAGPIX system (LXSARM-06) with post-hoc mean fluorescence quantification using xPONENT software. Atrial myeloperoxidase activity was evaluated using a colorimetric assay according to the manufacturer's directions (ab105136, Abcam).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!