The largest database of trusted experimental protocols

3 protocols using phenylacetaldehyde

1

Quantitative Analysis of Food Volatiles

Check if the same lab product or an alternative is used in the 5 most similar protocols
All chemicals used had a purity grade higher than 95%. Hexanal, benzaldehyde, 2-methylpropanal, nonanal, 2-methylbutanal, 3-methylbutanal, and 4-fluorobenzaldehyde standards were purchased from Sigma-Aldrich (Steinheim, Germany). Acetaldehyde, phenylAcetaldehyde, 5-(hydroxymethyl) furfural, 2-furaldehyde, and trans-2-nonenal were purchased from Acros Organics (Geel, Belgium). Absolute ethanol, acetonitrile, and methanol (HPLC grade 99.99%) was obtained from Sigma-Aldrich (Steinheim, Germany). Sodium chloride was obtained from Panreac (Barcelona, Spain). Ultra-pure water with a resistivity of >18 MΩ.cm (type 1) was obtained from a Millipore Simplicity® UV apparatus (Milford, MA, USA). The alkane solution (C7–C30) was obtained from Supelco (Sigma Aldrich, St. Louis, MO, USA).
+ Open protocol
+ Expand
2

Volatile Compound Analysis by GC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
All chemicals used had a purity grade higher than 95%. Hexanal, benzaldehyde, 2-methylpropanal, nonanal, 2-methylbutanal, 3-methylbutanal, and 4-fluorobenzaldehyde standards were purchased from Sigma-Aldrich (Steinheim, Germany). Acetaldehyde, phenylAcetaldehyde, 5-(hydroxymethyl) furfural, 2-furaldehyde and trans-2-nonenal were purchased from Acros Organics (Geel, Belgium). Absolute ethanol, acetonitrile, and methanol (all HPLC grade 99.99%) came from Sigma-Aldrich (Steinheim, Germany). Sodium chloride was obtained from Panreac (Barcelona, Spain). Ultra-pure water with a resistivity of >18 MΩ·cm (type 1) was obtained from a Millipore Simplicity® UV apparatus (Milford, MA, USA). The alkane solution (C7–C30) was obtained from Supelco (Sigma Aldrich, St. Louis, MO, USA).
+ Open protocol
+ Expand
3

Chemical Reagents for Organic Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Allyl-alcohol (99%), benzyl alcohol (99%), butanol (99.5%), 1-octanol (99%), phenyl acetaldehyde (98%, stabilized) and trimethylamine (99.7%) were purchased from Acros Organics. 1-Adamantyl isocyanide (95%), cyclohexanol (99%), cyclohexyl isocyanide (98%), 2-butanol (99.5%, anhydrous), 2,4-dinitrobenzaldehyde (97%), isobutyraldehyde (≥99.5%), 2-morpholinoethyl isocyanide (≥98%), tert-butanol (≥99.5%, anhydrous), tert-butyl isocyanide (98%), tetradecane (≥99.5%) and undecylenic aldehyde (95%) were obtained from Sigma Aldrich. Other chemicals used include: diazabicyclo[5.4.0]undec-7-ene (DBU, TCl, >98%), deuterated chloroform (CDCI3-d, Merck), dimethyl sulfoxide (DMSO, VWR, 99%) and trimethyl acetaldehyde (ABCR, 97%). Carbon dioxide (CO2) with purity over 99.9% was obtained from Air Liquide. Cyclohexane, ethyl acetate and dichloromethane were distilled before usage, while tetrahydrofuran (THF) was of technical grade and used without further purification. All other chemicals were used as received from the supplier.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!