Hp 1100 lc ms spectrometer

Manufactured by Agilent Technologies

The HP 1100 LC/MS spectrometer is a high-performance liquid chromatography (LC) and mass spectrometry (MS) instrument designed for analytical applications. It provides accurate mass measurements and identification of compounds in complex samples. The system integrates reliable LC separation with sensitive and selective MS detection, enabling users to obtain comprehensive analytical data.

Automatically generated - may contain errors

4 protocols using hp 1100 lc ms spectrometer

1

Analytical Techniques for Compound Purification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Compound purification was performed by column chromatography with Merck silica gel (40–63 µm) or flash chromatography (Biotage Isolera One, Uppsala, Sweden), as well as the adequate eluent for each compound. Reactions were monitored by thin layer chromatography (TLC), and compounds were detected under UV light (λ = 254 nm) and by using ethanolic solution of vanillin or ninhydrin. Melting points were determined using a Reichert Thermo Galen Kofler block and were uncorrected. 1H-NMR and 13C-NMR spectra were obtained in Bruker Avance 300 (300 MHz) and Bruker Avance 400 III HD (400 MHz) spectrometers. Samples were dissolved in CDCl3 or DMSO-d6, and TMS was used as internal standard for 1H NMR spectra. In 13C NMR spectra, central signals of solvent CDCl3 (77.0 ppm) and DMSO-d (39.5 ppm) were used as references. Chemical shifts (δ) are given in ppm, and coupling constants (J) are reported in Hz. Signal multiplicity is abbreviated as: singlet (s), doublet (d), triplet (t), pentuplet (p), and multiplet (m). IR spectra were recorded on a Perkin-Elmer Spectrum One B spectrometer. Low-resolution mass spectra were recorded on an Agilent HP 1100 LC/MS spectrometer, and high-resolution mass spectrometry (Exact Mass) was performed in an AGILENT 6520 Accurate-Mass QTOF LC/MS spectrometer. Elemental analysis was performed on elementary chemical analyzer (LECO CHNS-932).
+ Open protocol
+ Expand
2

Analytical Methods for Chemical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Compound purification: flash column chromatography (Merck, Silica Gel 60, 40–63 μm). Reaction monitoring: TLC on Merck's Silica Gel 60 F₂₅₄ plates, visualization: UV light (λ = 254 nm), and vanillin or ninhydrin stains. Following extraction, the organic phases were dried over anh. Mg2SO4, filtered and evaporated. Melting points are uncorrected (Reichert Thermo Galen Kofler block). 1H NMR and 13C NMR were recorded on Bruker Avance 300 (300 MHz), 400 III HD (400 MHz) and 500 II HD (500 MHz) spectrometers, samples dissolved in CDCl3 or DMSO-d6. In 13C NMR spectra, solvent signal were used as references, whereas TMS was used as the reference in 1H. Chemical shifts (δ) reported in ppm, coupling constants (J) in Hz, signal multiplicities are multiplet (m), singlet (s), doublet (d), triplet (t), quartet (q), septuplet (sept), doublet of doublets (dd), triplet of doublets (td). IR spectra (KBr discs) were recorded on a PerkinElmer Spectrum One B spectrometer. MS were recorded on an Agilent HP 1100 LC/MS spectrometer, and HRMS on an Agilent 6520 Accurate-Mass QTOF LC/MS. Elemental CNH analyses nitrones 119, and oxime 33 were recorded on a Carlo Erba EA 1108 (result: ±0.4% of expected).
+ Open protocol
+ Expand
3

Purification and Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Compound purification was performed by column chromatography with Merck Silica Gel (40–63 µm) or by flash chromatography (Biotage Isolera One equipment) and the adequate eluyent for each case. Reaction course was monitored by thin layer cromatography (t.l.c.), revealing with UV light (λ = 254 nm) and ethanolic solution of vanillin or ninhydrin. Melting points were determined using a Reichert Thermo Galen Kofler block and are uncorrected. Samples were dissolved in CDCl3 or DMSO-d6 using TMS as internal standard for 1H NMR spectra. In 13C NMR spectra, CDCl3 central signal (77.0 ppm) and DMSO-d (39.5 ppm) were used as references. 1H-NMR and 13C-NMR spectra were obtained in Bruker Avance 300 (300 MHz) and Bruker Avance 400 III HD (400 Hz) spectrometers. Chemical shifts (δ) are given in ppm. Coupling constants (J) are given in Hz. Signal multiplicity is abbreviated as: singlet (s), doublet (d), triplet (t), quartet (c), doublet of doublets (dd), triplet of doublets (td), or multiplet (m). IR spectra were recorded on a Perkin-Elmer Spectrum One B spectrometer. Units are cm−1. Low resolution mass spectra were recorded on an Agilent HP 1,100 LC/MS Spectrometer, whereas High Resolution mass spectrometry (Exact Mass) was performed in an AGILENT 6,520 Accurate-Mass QTOF LC/MS Spectrometer. Elemental analyses were performed in an Elementary Chemical Analyzer LECO CHNS-932.
+ Open protocol
+ Expand
4

Comprehensive Analytical Characterization Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Compound purification was performed by column chromatography with Merck Silica Gel (40–63 µm) or by flash chromatography and the adequate eluent for each case. Reaction course was monitored by thin layer chromatography (t.l.c.), revealing with UV light (λ = 254 nm) and ethanolic solution of vanillin or ninhydrin. Melting points were determined using a Reichert Thermo Galen Kofler block and were uncorrected. Samples were dissolved in CDCl3 or DMSO-d6 using TMS as internal standard for 1H NMR spectra. In 13C NMR spectra, CDCl3 central signal (77.0 ppm) and DMSO-d (39.5 ppm) were used as references. 1H-NMR and 13C-NMR spectra were obtained in Bruker Avance 300 (300 MHz) and Bruker Avance 400 III HD (400 Hz) spectrometers. Chemical shifts (δ) are given in ppm. Coupling constants (J) are given in Hz. Signal multiplicity is abbreviated as singlet (s), doublet (d), triplet (t), quartet (c), doublet of doublets (dd), triplet of doublets (td), or multiplet (m). IR spectra were recorded on a Perkin-Elmer Spectrum One B spectrometer. Units are cm−1. Low resolution mass spectra were recorded on an Agilent HP 1100 LC/MS Spectrometer, whereas High Resolution mass spectrometry (Exact Mass) was performed in an AGILENT 6520 Accurate-Mass QTOF LC/MS Spectrometer. Elemental analysis was performed in an Elementary Chemical Analyzer LECO CHNS-932.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.