The largest database of trusted experimental protocols

Pinnacle3 9

Manufactured by Philips
Sourced in United States, Sweden

The Pinnacle3 9.0 is a laboratory equipment product manufactured by Philips. It is designed to perform specific laboratory functions, but a detailed and unbiased description of its core function cannot be provided without the risk of extrapolation or interpretation.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using pinnacle3 9

1

Preoperative IMRT for Liver Tumors

Check if the same lab product or an alternative is used in the 5 most similar protocols
Preoperative IMRT was performed within 3 days after completion of all preoperative investigations and careful evaluation by the radiation clinicians. The gross tumor volume was defined as the tumor volume that was enhanced in the arterial phase on preoperative CE-MRI scans using the Pinnacle3 9.0 treatment planning systems (Philips Healthcare, Andover, MA, USA). The clinical tumor volume (CTV) was drawn by adding 5–10 mm to the gross tumor volume. The planning target volume (PTV) was generated by adding 5mm in the anterior–posterior and left–right directions and 10mm in the cranial–caudal direction from the CTV considering respiratory liver motion and set-up errors. The prescription dose to 95% of the PTV was planned at 50-60 Gy in 25-30 fractions over 5-6 weeks. The final prescription dose was determined according to dose constraints for organs at risk.
+ Open protocol
+ Expand
2

Automated and Manual Contouring Protocol for Anatomical Structures

Check if the same lab product or an alternative is used in the 5 most similar protocols
A contouring protocol set image window levels to Window/Level=400/800 HU and described allowable techniques/tools. All eight rectangular prisms were auto-contoured using auto-threshold at recommended threshold values or other automated tools (e.g. Oncentra's magic-wand tool). Rectangular prisms 1, 4 and 8 (Supplementary Fig. 1.) were manually contoured. Bounding boxes in auto-contouring and zoom functions were allowed. The breast contour was manually delineated; allowing interpolation between slices and/or copy to next slice. The triangular prism and cylinder were both delineated using automated tools (such as auto-threshold) and manually. All eight observers were blind to others contours.
The TPSs used for contouring were; Eclipse Planning System 11.0.64 (Varian Medical Systems, Palo Alto Canada): 2 sites, Oncentra (Elekta, Stockholm Sweden): 2 sites, Pinnacle 3 9.0 (Philips, Netherlands): 2 sites, and FocalSim 4.80.01 (Elekta, Stockholm Sweden): 2 sites. These contours were then exported and collated in CERR.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!