H c p f qnp gradient probe

Manufactured by Bruker

The H/C/P/F QNP gradient probe is a laboratory instrument designed for Nuclear Magnetic Resonance (NMR) spectroscopy. It is capable of detecting and analyzing hydrogen (H), carbon (C), phosphorus (P), and fluorine (F) nuclei within a sample. The probe utilizes gradient coils to provide spatial encoding of the sample, enabling more advanced NMR experiments and analysis.

Automatically generated - may contain errors

7 protocols using h c p f qnp gradient probe

1

NMR Spectroscopy Protocol for Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 3

1H NMR were recorded at 400 or 500 MHz (Bruker DRX-400 Bruker with a H/C/P/F QNP gradient probe) spectrometer and 13C NMR spectra were recorded at 125 MHz (Bruker DRX 500 with broadband, inverse triple resonance, and high resolution magic angle spinning HR-MA probe spectrometer); chemical shifts are reported in δ (ppm) relative to the internal reference chloroform-d (CDCl3, 7.27 ppm).

+ Open protocol
+ Expand
2

Characterization of Chemical Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H NMR were recorded at 400 or 500 MHz (Bruker DRX-400 Bruker with a H/C/P/F QNP gradient probe) spectrometer and 13C NMR spectra were recorded at 125 MHz (Bruker DRX 500 with broadband, inverse triple resonance, and high resolution magic angle spinning, HR-MA probe spectrometer); chemical shifts are reported in δ (ppm) relative to the internal chloroform-d (CDCl3, 7.27 ppm). FAB (HRMS) spectra were recorded with a LCT Premier (Waters Corp., Milford, MA). The purity of all compounds was determined to be >95% purity as determined by 1H NMR and 13C NMR spectra, unless otherwise noted. The most active five compounds were verified for >95% purity by HPLC analyses. TLC was performed on glass backed silica gel plates (Uniplate) with spots visualized by UV light. All solvents were reagent grade and, when necessary, were purified and dried by standard methods. Concentration of solutions after reactions and extractions involved the use of a rotary evaporator operating at reduced pressure.
+ Open protocol
+ Expand
3

Characterization of Organic Compounds by NMR and Mass Spectrometry

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H NMR were recorded at 400 or 500 MHz (Bruker DRX- 400 Bruker with a H/C/P/F QNP gradient probe) spectrometer and 13C NMR spectra were recorded at 125 MHz (Bruker DRX 500 with broadband, inverse triple resonance, and high resolution magic angle spinning HR-MA probe spectrometer); chemical shifts are reported in δ (ppm) relative to the internal reference CDCl3-d (CDCl3, 7.27 ppm). FAB (HRMS) spectra were recorded with a LCT Premier (Waters Corp., Milford, MA) spectrometer. The purity of all compounds was determined to be >95% as determined by 1H NMR and 13C NMR spectra, unless otherwise noted. TLC was performed on glass- backed silica gel plates (Uniplate) with spots visualized by UV light. All solvents were reagent grade and, when necessary, were purified and dried by standard methods. Concentration of solutions after reactions and extractions involved the use of a rotary evaporator operating at reduced pressure.
+ Open protocol
+ Expand
4

NMR Spectroscopic Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 3

1H NMR were recorded at 400 or 500 MHz (Bruker DRX-400 Bruker with a H/C/P/F QNP gradient probe) spectrometer and 13C NMR spectra were recorded at 125 MHz (Bruker DRX 500 with broadband, inverse triple resonance, and high resolution magic angle spinning HR-MA probe spectrometer); chemical shifts are reported in δ (ppm) relative to the internal reference chloroform-d (CDCl3, 7.27 ppm).

+ Open protocol
+ Expand
5

NMR Spectroscopic Analysis Procedure

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 3

1H NMR were recorded at 400 or 500 MHz (Bruker DRX-400 Bruker with a H/C/P/F QNP gradient probe) spectrometer and 13C NMR spectra were recorded at 125 MHz (Bruker DRX 500 with broadband, inverse triple resonance, and high resolution magic angle spinning HR-MA probe spectrometer); chemical shifts are reported in δ (ppm) relative to the internal reference chloroform-d (CDCl3, 7.27 ppm).

+ Open protocol
+ Expand
6

Detailed Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H NMR were recorded at 400 or 500 MHz (Bruker DRX- 400 Bruker with a H/C/P/F QNP gradient probe) spectrometer and 13C NMR spectra were recorded at 125 MHz (Bruker DRX 500 with broadband, inverse triple resonance, and high resolution magic angle spinning HR-MA probe spectrometer); chemical shifts are reported in δ (ppm) relative to the internal reference CDCl3 (CDCl3, 7.26 ppm). FAB (HRMS) spectra were recorded with a LCT Premier (Waters Corp., Milford, MA) spectrometer and IR spectra were recorded on a Magna FT-IR spectrometer (Nicolet Instrument Corporation, Madison, WI). The purity of all compounds was determined to be >95% as determined by 1H NMR and 13C NMR spectra, unless otherwise noted. TLC was performed on glass- backed silica gel plates (Uniplate) with spots visualized by UV light. All solvents were reagent grade and, when necessary, were purified and dried by standard methods. Concentration of solutions after reactions and extractions involved the use of a rotary evaporator operating at reduced pressure. Detailed experimental procedures can be found in the supporting information.
+ Open protocol
+ Expand
7

NMR Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
1HNMR were recorded at 400 or 500 MHz (Bruker DRX-400 Bruker with a H/C/P/F QNP gradient probe) spectrometer and 13C NMR spectra were recorded at 100 or 125 MHz (Bruker DRX 500 with broadband, inverse triple resonance, and high resolution magic angle spinning HR-MA probe spectrometer); chemical shifts are reported in δ (ppm) relative to the internal reference chloroform-d (CDQ3, 7.27 ppm) or dimethyl sulfoxide-d6 (DMSO-d6, 2.50 ppm). High resolution mass spectra (FAB) were recorded with a LCT Premier (Waters Corp., Milford, MA) spectrometer. The purity of all compounds was determined to be >95% as determined by HPLC analysis. TLC was performed on glassbacked silica gel plates (Uniplate) with spots visualized by UV light. All solvents were reagent grade and when necessary, were purified and dried by standard methods. Concentration of solvents occurred via the use of a rotary evaporator operating at reduced pressure.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!