The largest database of trusted experimental protocols

Pp ods column

Manufactured by Eicom

The PP-ODS column is a type of reversed-phase chromatography column used for liquid chromatography (LC) analysis. It is designed with a stationary phase composed of polypropylene material and octadecylsilane (ODS) bonded ligands. The column's core function is to facilitate the separation and analysis of a wide range of organic compounds in various sample matrices.

Automatically generated - may contain errors

2 protocols using pp ods column

1

Microdialysis of Dopamine in Mouse NAc

Check if the same lab product or an alternative is used in the 5 most similar protocols
Microdialysis was performed as described previously22 (link)46 (link). Briefly, the animals were anesthetized with sodium pentobarbital, and surgery was performed to implant a guide cannula (AG-4; EICOM, Kyoto, Japan) into the nucleus accumbens. On the following day, a dialysis probe (AI-4-1, 1-mm membrane length; EICOM) was inserted through the guide cannula and was perfused with artificial cerebrospinal fluid (148 mM NaCl, 2.7 mM KCl, 1.2 mM CaCl2, and 0.85 mM MgCl2) at a flow rate of 1 μl min–1. After an equilibration period of one hour, samples were collected every 20 minutes. After collection of at least five baseline fractions, mice were administered MAP (1 mg kg–1, i.p.), and 6 more fractions of samples were collected. The concentration of dopamine in the samples was measured by HPLC on a 4.6 by 30 mm PP-ODS column (EICOM) that was maintained at 25 °C and equipped with an electrochemical detection system (HTEC-500, EICOM) and PowerChrom (EICOM).
+ Open protocol
+ Expand
2

HPLC-based Neurotransmitter Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
The collected microdialysate samples (10 μL) were separated by HPLC using a PP-ODS column (EICOM) and a mobile phase containing 0.1 mol/L phosphate buffer (pH 6.0), 1% methanol, 50 mg L−1 ethylenediamine tetraacetic acid disodium, and 500 mg L−1 sodium 1-decanesulfonate at a flow rate of 0.5 mL min−1. The peaks corresponding to 5-HT and dopamine were amperometrically detected using a graphite electrode set at 400 mV with an Ag/AgCl reference electrode (RE-100; EICOM). Online data acquisition was performed using PowerChrom software (Version 2.2; AD Instruments Pty Ltd., Nagoya, Aichi, Japan). Before performing the microdialysis, the retention time of the HPLC peak for 5-HT and dopamine was determined using a standard solution. The peak height (mV) of 5-HT and dopamine at each measurement was converted into a percentage of the average of the last 4 pre-drug baseline values (percentage of baseline).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!