The largest database of trusted experimental protocols

2 protocols using dextran dex

1

Biopolymer-based Antimicrobial Composite

Check if the same lab product or an alternative is used in the 5 most similar protocols
Dextran (Dex; Mw −70 kDa) was purchased from Macklin Co. Ltd. (Shanghai, China). Sodium hyaluronic acid (HA; Mw = 200 kDa) was obtained from Shandong Freda Biochem Co., Ltd. (Linyi, China). Chitosan quaternary ammonium salt (HACC, 90% degree of substitution) was obtained from Guangdong Wengjiang Chemical Reagent Co. Ltd. (Shaoguan, China). Hyaluronidase from purified bovine testes, silver nitrate, adipic dihydrazide (ADH) and hydroxy-benzotriazole (HOBt) were purchased from Aladdin Biochemical Technology Co. Ltd. (Shanghai, China). 1-ethyl-3-[3-(dimethylamino) propyl] carbodiimide (EDC) and sodium periodate were purchased from Guangzhou Chemical Reagent Factory. CCK-8 was purchased from Shanghai Beyotime Biotechnology Co. Ltd. (Shanghai, China) E. coli (ATCC8739), S. aureus (ATCC14458) and P. aeruginosa (CMCCB10104) were obtained from the Department of Biomedical Engineering of Jinan University and were maintained on solid agar medium at 4 °C. All other reagents were analytical grade and used without further processing.
+ Open protocol
+ Expand
2

Synthesis of Multifunctional Hydrogel Biomaterials

Check if the same lab product or an alternative is used in the 5 most similar protocols
Poly(ethylene glycol) (PEG, Mw ~8000), Poly(vinyl alcohol) (PVA, Mw: 89,000–98,000, 99% hydrolyzed), Poly(2-ethyl-2-oxazoline) (PEtOx, Mw~50, 000), sodium citrate, Poly(ethylene glycol) diacrylate (PEGDA, Mn~575), sodium alginate, 2-Hydroxy-4′-(2-hydroxyethoxy)−2-methylpropiophenone (Irgacure 2959), N,N′-methylenebisacrylamide (MBAA), were purchased from Sigma-Aldrich. Dextran (DEX, Mw ~10,000, 40,000, and 500,000) and Nile red were purchased from Macklin. Acrylamide and lithium phenyl-2,4,6 trimethylbenzoylphosphinate (LAP) were purchased from TCI. Rhodamine 6 G, Fluorescein isothiocyanate (FITC) labeled Poly-l-lysine (FITC-PLL, Mw ~30,000–70,000), and Fluorescein isothiocyanate–dextran (FITC-dextran, Mw ~40, 000) were purchased from Sigma-Aldrich. Rhodamine-labeled PEG (Rh-PEG, Mw ~40,000) was purchased from Aladdin. Nucleic acid sequences of Cy5-DNA were synthesized by Integrated DNA Technology (IDT). Calcein was purchased from J&K scientific. Millipore Milli-Q water (18.2 MΩ, pH = 7) was used in all experiments. All materials were used as received without further purification.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!