The largest database of trusted experimental protocols

Triacylglycerol assay kit

Manufactured by Nanjing Jiancheng
Sourced in China

The Triacylglycerol Assay kit is a laboratory tool designed for the quantitative determination of triacylglycerol levels in various sample types. It provides a standardized and reliable method for the analysis of this important lipid class.

Automatically generated - may contain errors

6 protocols using triacylglycerol assay kit

1

Quantification of Cellular and Hepatic Lipids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Lipids in cells were extracted using 1.5 mL/well cell lipid extracting solution on the ice for 1 h. The solution was dried using nitrogen and then dissolved in 80 μL of lipid lysis solution for TG quantification by triacylglycerol assay kit (NANJINGJIANCHENG Bio, China). Subsequently, the cellular protein was extracted with 0.2 mL/well of RIPA lysis buffer on ice for 20 min and measured by BCA protein assay kit (Dingguochangsheng, China). Liver tissue was homogenized with liver lipid extraction (mass (g): volume (mL) = 1:9) and the supernatant was obtained by centrifugation at 3000 rpm for 10 min at 4 °C. The supernatant was dried by nitrogen and then residue was dissolved in 3 mL lipid lysis solution for lipid quantification with triacylglycerol assay kit and total cholesterol assay kit (NANJINGJIANCHENG Bio, China). The result is expressed as micromoles of lipid in per gram of cellular protein or per gram of liver weight.
+ Open protocol
+ Expand
2

Serum Lipid Profile in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Peripheral blood of mice were collected from the posterior orbital venous plexus. The blood was centrifuged for 10 min under the rotate speed of 3000 rpm and the serum was collected for the analysis of serum lipids. The detection is performed according to the speci cation of enzymatic biochemical kits (Nanjing Jiancheng) via microplate reader (TECAN): Total Cholesterol Assay kit (Cat A111-1), Triacylglycerol Assay kit (Cat A110-1), Low Density Lipoprotein Cholesterol Assay kit (Cat A113-1), and High Density Lipoprotein Cholesterol Assay kit (Cat A112-1). The level of non-HDL-C was calculated by HDL-C subtracted from TC content.
+ Open protocol
+ Expand
3

Enzymatic Lipid Profiling Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Enzymatic biochemical kits (Nanjing Jiancheng) were used to determine serum lipids via microplate reader (TECAN): Total Cholesterol Assay kit (Cat A111-1), Triacylglycerol Assay kit (Cat A110-1), Low Density Lipoprotein Cholesterol Assay kit (Cat A113-1), and High Density Lipoprotein Cholesterol (Cat A112-1).
+ Open protocol
+ Expand
4

Serum Lipid Profile in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Peripheral blood of mice were collected from the posterior orbital venous plexus. The blood was centrifuged for 10min under the rotate speed of 3000rpm and the serum was collected for the analysis of serum lipids. The detection is performed according to the speci cation of enzymatic biochemical kits (Nanjing Jiancheng) via microplate reader (TECAN): Total Cholesterol Assay kit (Cat A111-1), Triacylglycerol Assay kit (Cat A110-1), Low Density Lipoprotein Cholesterol Assay kit (Cat A113-1), and High Density Lipoprotein Cholesterol Assay kit (Cat A112-1). The level of non-HDL-C was calculated by HDL-C subtracted from TC content.
+ Open protocol
+ Expand
5

Serum Lipid and Enzyme Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
After blood was set at room temperature for 30 min, serum was separated by centrifuging at 3500 rpm for 20 min at 4 °C. Serum TG and TC contents were measured by triacylglycerol assay kit, total cholesterol assay kit (NANJINGJIANCHENG Bio, China), transaminase levels were detected using alanine aminotransferase assay kit and aspartate aminotransferase assay kit (NANJINGJIANCHENG Bio, China), and inflammatory factors levels were measured using Rat IL-1β ELISA kit (CUSABIO, China), Rat IL-4 ELISA kit and Rat TNF-α ELISA kit (ExCELL Bio, China).
+ Open protocol
+ Expand
6

Murine Serum Lipid Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Peripheral blood of mice were collected from the posterior orbital venous plexus. The blood was centrifuged for 10 min under the rotate speed of 3000 rpm and the serum was collected for the analysis of serum lipids. The detection is performed according to the specification of enzymatic biochemical kits (Nanjing Jiancheng) via microplate reader (TECAN): Total Cholesterol Assay kit (Cat A111–1), Triacylglycerol Assay kit (Cat A110–1), Low Density Lipoprotein Cholesterol Assay kit (Cat A113–1), and High Density Lipoprotein Cholesterol Assay kit (Cat A112–1). The level of non-HDL-C was calculated by HDL-C subtracted from TC content.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?