The largest database of trusted experimental protocols

2 protocols using u 47700

1

Opioid and Synthetic Opioid Separations

Check if the same lab product or an alternative is used in the 5 most similar protocols
The run buffer used for opioid and synthetic opioid separations was 12 mmol/L acetic acid, 3.3 mmol/L ammonium acetate pH 4.4 (Sigma-Aldrich, St. Louis, MO, USA) in ultrapure water (Millipore Milli-Q, 18.0 MΩ-cm). Acetaminophen, caffeine, mannitol, procaine, quinine, and methanol were all purchased from Sigma-Aldrich (St. Louis, MO, USA).
All fentanyl analogues (acetyl fentanyl, acryl fentanyl, benzyl fentanyl, butyryl fentanyl, furanyl fentanyl, methacryl fentanyl, methoxyacetyl fentanyl, phenyl fentanyl, valeryl fentanyl) were purchased as hydrochloride salts from Cayman Chemical (Ann Arbor, MI, USA) or, when possible, as 1 mg·mL−1 methanolic solutions. Powdered standards and samples were dissolved gravimetrically in methanol (Sigma-Aldrich, St. Louis, MO). The remaining opioids and narcotics (heroin, fentanyl, cocaine, U-47700) were purchased as 1 mg·mL−1 solutions in methanol or acetonitrile from Cerilliant (Round Rock, TX, USA). All sample dilutions were prepared in run buffer, and methanol was added as necessary to allow for a constant 4 % by volume organic solvent across all analyses. When increased analyte concentrations were desired, standards were concentrated to assure each sample contained a maximum of 4 % (v/v) solvent.
+ Open protocol
+ Expand
2

Analytical Protocol for Novel Psychoactive Substances

Check if the same lab product or an alternative is used in the 5 most similar protocols
Wa t e r ( C h r o m a s o lv ® L C -M S ) , a c e t o n i t r i l e (Chromasolv ® LC-MS), methanol (Chromasolv ® LC-MS) ethyl acetate, and formic acid were purchased from Sigma-Aldrich (Steinheim, Germany); ammonium formate from Sigma-Aldrich (Bangalore, India); ammonium carbonate from Fluka (Buchs, Switzerland); 4-CMC, U-47700, N-ethylhexedrone, sertraline, fentanyl-d 5 , quetiapine-d 8 and diazepam-d 5 from Cerilliant (Round Rock, TX, USA); adinazolam, 4-methylmethcathinoned 3 (4-MMC-d 3 ), 4-CIC from LGC Standards (Dziekanów Leśny, Poland). The internal standards (ISs) were prepared in methanol.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!